--- title: "Configuring MTA event notification thresholds" slug: "configuring-mta-event-notification-thresholds" tags: ["Product Usage", "CMS 11.x", "EX 11.x", "FX 11.x", "AX 11.x", "NX 11.x", "IVX 11.x", "Network Security"] updated: 2026-08-21T15:38:06Z published: 2026-08-24T18:57:06Z canonical: "docs.trellix.com/configuring-mta-event-notification-thresholds" stale: true --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.trellix.com/llms.txt > Use this file to discover all available pages before exploring further. # Configuring MTA event notification thresholds If the total number of bypassed emails since the last MTA health check exceeds a specific threshold, an event notification is sent to the configured MTA alias. If the total number of deferred emails since the last MTA health check exceeds a specific threshold, another event notification is sent. (For more information about congestion policy, see the *Email Security — Server User Guide*.) These thresholds and other MTA event notification settings are described in the following table. > [!WARNING] > Important > > These settings are used only when the Email Security — Server appliance is deployed inline in MTA mode and configured in the Block or Monitor analysis mode. For details, see [Analysis modes](/data-and-email/docs/analysis-modes) . > [!NOTE] > Note > > Individual MTA events cannot be enabled or disabled. ### MTA Event Notification Settings | Web UI field | CLI parameter | description | | --- | --- | --- | | Enable | enable | Enables MTA event notifications to be sent to the alias configured as the MTA notification recipient. (The **MTA** checkbox must also be selected for this recipient.) | | — | interval | The number of minutes between each MTA health check. | | Bypass threshold | bypass-threshold | When the total number of bypassed emails exceeds this value, an event notification is triggered. Valid values are 0-100,000. | | Deferred Threshold | defer-threshold | When the total number of deferred emails exceeds this value, an event notification is triggered. Valid values are 0-100,000. | | Backoff period | backoff | How often event notifications are sent for each threshold, in seconds. Valid values are 1800-7200. For example, a value of 3600 means a notification will be sent every hour as long as the congestion condition exists. | **Prerequisites** - Operator or Admin access - An MTA email alias configured as described in [Configuring email recipients using the Web UI](/data-and-email/docs/configuring-email-recipients-using-the-web-ui)