--- title: "Front control panel" slug: "front-control-panel-7" tags: ["Hardware", "DLPNP 11.10.x", "DLPNP 11.11.x"] updated: 2026-09-02T05:55:57Z published: 2026-09-02T05:55:57Z canonical: "docs.trellix.com/front-control-panel-7" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.trellix.com/llms.txt > Use this file to discover all available pages before exploring further. # Front control panel The control panel is on the front of the chassis. **Trellix DLP 6600 front control panel**![Trellix DLP 6600 front control panel](https://cdn.us.document360.io/0d453a50-e1da-4d4a-9409-fea7959614d8/Images/Documentation/uuid-33016b5c-6309-d131-1c88-009aa63bdb32(1).png?sv=2026-02-06&spr=https&st=2026-11-22T13%3A24%3A28Z&se=2026-11-22T14%3A24%3A28Z&sr=c&sp=r&sig=hgaoht%2F%2Fu1jpgCwAqAn37eJMxBG080lokTrRDYGvKLg%3D) | 1. System ID button 2. NMI button (recessed) 3. NIC 2 activity 4. System cold reset button 5. Hard drive activity 6. Power button 7. NIC 1 activity 8. System status | | --- | **Trellix DLP 6600 system status indicator light states** | Color | State | Status | | --- | --- | --- | | Green | Solid | System booted and ready | | Blink | System degraded: - Non-critical threshold crossed - Temperature - Voltage - Power supply input or output - Fan redundancy lost, sufficient system cooling maintained - Power supply redundancy lost - Unable to use all of the installed memory — one or more DIMMS failed or disabled, but functional memory remains available - Battery failure - Power unit sensor offset error asserted - HDD HSC offline or degraded - BMC executing uBoot - BMC Watchdog has reset the BMC | | Amber | Solid | Fatal alarm — System has failed or shut down: - CPU CATERR signal asserted - CPU 1 missing - CPU Thermal Trip - CPU ERR2 signal asserted - MSID mismatch detected - DIMM failure when only one DIMM is present - Runtime memory uncorrectable error in non-redundant mode - DIMM Thermal Trip or equivalent - SSB Thermal Trip or equivalent - BMC/Video memory test failed - Both uBoot BMC FW images are bad - 240 VA fault - Power fault - Fatal error in processor initialization - Processor families not identical - Processor models not identical - Processor core/thread counts not identical - Processor cache sizes not identical - Unable to synchronize processor frequency - Unable to synchronize QPI link frequency | | Blink | Non-fatal alarm — System is likely to fail: - Critical threshold crossed - Temperature - Voltage - Power supply input or output - Voltage regulator device (VRD) hot asserted - Minimum number of fans to cool the system not present or failed - Hard drive fault - Insufficient power supplies present - Correctable memory error threshold crossed for a failing DDR3 DIMM when the system operates in a non-redundant mode | | Off | Off | System turned off |