Technical specifications (DLP 8800)

Prev Next

Before you set up the Trellix DLP 8800 hardware appliance, review the specifications.

Specifications

Specification

Details

Part #

DLP-8800-A

SKU

DLP-8800-AA

Form Factor

1U rack mount

Supported software version

11.10.300 or later

CPU

2 x Intel CPU SPR, XEON SILVER 4410Y, 12C, 2.0 GHZ, 30MB CACHE

Memory

4 x 16GB, DDR5, 4800MHZ, RDIMM, ECC, 1RX8

Hard Drives

2x HDD, 0.96 TB

Network Interfaces

2 x 1GbE /10GbE PCIe 3.0 RJ45 ports

2 x 1Gbps OCP ports RJ45

4 x1GbE /10GbE PCIe 3.0 SFP ports

USB Ports

Front: 2 x USB 2.0 Ports

Back: 2 x USB 3.1 Ports

Serial Interface

1 COM Port

RAID

SW RAID

SSD

2 x SSD, 2.5", 960GB, SATA, MICRON 5400MAX

Remote Access

Dedicated IPMI LAN

Motherboard

X13DDW-A

Dimension

17.2” W x 23.5” D x 1.7” H

(437mm W x 597 mm D x 43 mm H)

Maximum weight

40 lbs or 18.1 kg

Remote Management

Built-in BMC/RMM 1GbE (Gigabit Ethernet) LAN port

Operating temperature

10º to 35º C (50º to 95º F)

Humidity range

8% to 90%, non-condensing

Power Rating

2 x 1200W hot-swap power supply modules



Power Specifications

Voltage

Auto switch 110/220 V

Input Voltage Range

100-127Vac / 9A-7.5A / 50-60Hz

200-240Vac / 6A-4.5A / 50-60Hz

Maximum Amps

12.5A(100-127) 7.5A (220-240)

Power Consumption

592.8 W

Power Rating

1200 W

Power Supply Unit

1200 W, TITANIUM PSU redundant

Total BTU/h

2023.2

Environmental and Regulatory Specifications

Operating Temperature

10°C ~ 35°C (50°F ~ 95°F)

Non-Operating Temperature

-40°C to 60°C (-40°F to 140°F)

Acoustic Noise

ISO 7779 [Bystander test with fan speed control enabled and full speed]

Shock, Operating

2.5 ms duration, 20G, half-sine, one shock on each side

Shock, non-operating

10 ms duration, 10-20G, square wave, one shock on each side

Vibration (Sinusoidal) operating

0.25 G at 5 to 200 Hz. Approx 15 min/axis

Vibration (Sinusoidal) Non-operating

0.50 G at 5 to 200 Hz. Approx 15 min/axis

Vibration (Random) operating

0.40 rms at 5 to 200Hz. Approx 60min/axis

Vibration (Random) Non-operating

0.98 rms at 5 to 200Hz. Approx 60min/axis

Operating Relative Humidity

8% to 90% (non-condensing)

Non-operating Relative Humidity

5% to 95% (non-condensing)

Safety

EN 60950-1:2006/A11:2009/A1:2010/A12:2011

Yes

EN 62368-1:2014

Yes

IEC 62368-1:2014

Yes

UL 62368-1: 2014

Yes

EN 62368-1:2018

Yes

IEC 62368-1:2018

Yes

China GB4943.1-2011

Yes

Electromagnetic compatibility (EMC)

Title 47 of the CFR, Part 15, Class A

Yes

ICES-003 Issue 4, February 7, 2004 Class A

Yes

EN55032:2015

Yes

EN 55035:2017

Yes

China GB17625.1:2012

Yes

KS C 9832: 2019 and KS C 9835:2019

Yes

CISPR 32:2015

Yes

VCCI-CISPR 32:2016

Yes

Emissions (Australia/NZ)

Yes

Country Of Approval

USA

Yes

Canada

Yes

European Union (CE Mark)

Yes

China CCC

Yes

EAC (Euro-Asia Conformity) Russia, Kazakhstan, and Belarus

Yes

South Africa LoA

Yes

Korea MISP

Yes

Australia/New Zealand

Yes

Israel

Yes

Japan

Yes