The new docs.trellix.com features a modernized UI and AI-powered conversational search. Content is currently available in English, with additional languages expected in November 2026. We hope you enjoy the updated experience.

Technical specifications of DLP 8800

Prev Next

Before you set up the Trellix DLP 8800 hardware appliance, review the specifications.

Specifications

Specification

Details

Part #

DLP-8800-A

SKU

DLP-8800-AA

Form Factor and dimension

1U; 17.2” x 1.7” x 23.5” (depth) (43.7 x 4.3 x 60) in cm

Supported software version

11.10.300 or later

CPU

2 x Intel CPU SPR, XEON SILVER 4410Y, 12C, 2.0 GHZ, 30MB CACHE

Memory

Total 64GB DDR5 RDIMM ECC

Hard Drives

2x HDD, 0.96 TB

Network Interfaces

2 x 1GbE /10GbE PCIe 3.0 RJ45 ports

2 x 1Gbps OCP ports RJ45

USB Ports

Front: 2 x USB 2.0 Ports

Back: 2 x USB 3.1 Ports

Serial Interface

1 COM Port

RAID

SW RAID

SSD

2 x SSD, 2.5", 960GB, SATA, MICRON 5400MAX

Remote Access

Dedicated IPMI LAN

Motherboard

X13DDW-A

Maximum weight

40 lbs or 18.1 kg

Remote Management

Built-in BMC/RMM 1GbE (Gigabit Ethernet) LAN port

Operating temperature

10º to 35º C (50º to 95º F)

Humidity range

8% to 90%, non-condensing

Power Rating

2 x 1200W hot-swap power supply modules



Power Specifications

Voltage

Auto switch 110/220 V

Input Voltage Range

100-127Vac / 9A-7.5A / 50-60Hz

200-240Vac / 6A-4.5A / 50-60Hz

Maximum Amps

12.5A(100-127) 7.5A (220-240)

Power Consumption

592.8 W

Power Rating

1200 W

Power Supply Unit

1200 W, TITANIUM PSU redundant

Total BTU/h

2023.2

Environmental and Regulatory Specifications

Operating Temperature

10°C ~ 35°C (50°F ~ 95°F)

Non-Operating Temperature

-40°C to 60°C (-40°F to 140°F)

Acoustic Noise

ISO 7779 [Bystander test with fan speed control enabled and full speed]

Shock, Operating

2.5 ms duration, 20G, half-sine, one shock on each side

Shock, non-operating

10 ms duration, 10-20G, square wave, one shock on each side

Vibration (Sinusoidal) operating

0.25 G at 5 to 200 Hz. Approx 15 min/axis

Vibration (Sinusoidal) Non-operating

0.50 G at 5 to 200 Hz. Approx 15 min/axis

Vibration (Random) operating

0.40 rms at 5 to 200Hz. Approx 60min/axis

Vibration (Random) Non-operating

0.98 rms at 5 to 200Hz. Approx 60min/axis

Operating Relative Humidity

8% to 90% (non-condensing)

Non-operating Relative Humidity

5% to 95% (non-condensing)

Safety

EN 60950-1:2006/A11:2009/A1:2010/A12:2011

Yes

EN 62368-1:2014

Yes

IEC 62368-1:2014

Yes

UL 62368-1: 2014

Yes

EN 62368-1:2018

Yes

IEC 62368-1:2018

Yes

China GB4943.1-2022

Yes

Electromagnetic compatibility (EMC)

Title 47 of the CFR, Part 15, Class A

Yes

Canada ICES-003 Issue 7, February, 2020 Class A

Yes

EN55032:2015

Yes

EN 55035:2017

Yes

China GB17625.1:2022

Yes

KS C 9832: 2019 and KS C 9835:2019

Yes

CISPR 32:2015

Yes

VCCI-CISPR 32:2016

Yes

Emissions (Australia/NZ)

Yes

Country Of Approval

USA

Yes

Canada

Yes

European Union (CE Mark)

Yes

China CCC

Yes

South Africa LoA

Yes

Korea MISP

Yes

Australia/New Zealand

Yes

Israel

Yes

Japan

Yes