--- title: "Technical specifications of DLP 8800" slug: "technical-specifications-of-dlp-8800" tags: ["DLPNP 11.10.x", "Hardware"] updated: 2026-11-04T16:51:45Z published: 2026-11-04T16:51:45Z canonical: "docs.trellix.com/technical-specifications-of-dlp-8800" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.trellix.com/llms.txt > Use this file to discover all available pages before exploring further. # Technical specifications of DLP 8800 Before you set up the Trellix DLP 8800 hardware appliance, review the specifications. **Specifications** | Specification | Details | | --- | --- | | Part # | DLP-8800-A | | SKU | DLP-8800-AA | | Form Factor and dimension | 1U; 17.2” x 1.7” x 23.5” (depth) (43.7 x 4.3 x 60) in cm | | Supported software version | 11.10.300 or later | | CPU | 2 x Intel CPU SPR, XEON SILVER 4410Y, 12C, 2.0 GHZ, 30MB CACHE | | Memory | Total 64GB DDR5 RDIMM ECC | | Hard Drives | 2x HDD, 0.96 TB | | Network Interfaces | 2 x 1GbE /10GbE PCIe 3.0 RJ45 ports 2 x 1Gbps OCP ports RJ45 | | USB Ports | Front: 2 x USB 2.0 Ports Back: 2 x USB 3.1 Ports | | Serial Interface | 1 COM Port | | RAID | SW RAID | | SSD | 2 x SSD, 2.5", 960GB, SATA, MICRON 5400MAX | | Remote Access | Dedicated IPMI LAN | | Motherboard | X13DDW-A | | Maximum weight | 40 lbs or 18.1 kg | | Remote Management | Built-in BMC/RMM 1GbE (Gigabit Ethernet) LAN port | | Operating temperature | 10º to 35º C (50º to 95º F) | | Humidity range | 8% to 90%, non-condensing | | Power Rating | 2 x 1200W hot-swap power supply modules | | Power Specifications | | --- | | Voltage | Auto switch 110/220 V | | Input Voltage Range | 100-127Vac / 9A-7.5A / 50-60Hz 200-240Vac / 6A-4.5A / 50-60Hz | | Maximum Amps | 12.5A(100-127) 7.5A (220-240) | | Power Consumption | 592.8 W | | Power Rating | 1200 W | | Power Supply Unit | 1200 W, TITANIUM PSU redundant | | Total BTU/h | 2023.2 | | Environmental and Regulatory Specifications | | --- | | Operating Temperature | 10°C ~ 35°C (50°F ~ 95°F) | | Non-Operating Temperature | -40°C to 60°C (-40°F to 140°F) | | Acoustic Noise | ISO 7779 [Bystander test with fan speed control enabled and full speed] | | Shock, Operating | 2.5 ms duration, 20G, half-sine, one shock on each side | | Shock, non-operating | 10 ms duration, 10-20G, square wave, one shock on each side | | Vibration (Sinusoidal) operating | 0.25 G at 5 to 200 Hz. Approx 15 min/axis | | Vibration (Sinusoidal) Non-operating | 0.50 G at 5 to 200 Hz. Approx 15 min/axis | | Vibration (Random) operating | 0.40 rms at 5 to 200Hz. Approx 60min/axis | | Vibration (Random) Non-operating | 0.98 rms at 5 to 200Hz. Approx 60min/axis | | Operating Relative Humidity | 8% to 90% (non-condensing) | | Non-operating Relative Humidity | 5% to 95% (non-condensing) | | Safety | | --- | | EN 60950-1:2006/A11:2009/A1:2010/A12:2011 | Yes | | EN 62368-1:2014 | Yes | | IEC 62368-1:2014 | Yes | | UL 62368-1: 2014 | Yes | | EN 62368-1:2018 | Yes | | IEC 62368-1:2018 | Yes | | China GB4943.1-2022 | Yes | | Electromagnetic compatibility (EMC) | | --- | | Title 47 of the CFR, Part 15, Class A | Yes | | Canada ICES-003 Issue 7, February, 2020 Class A | Yes | | EN55032:2015 | Yes | | EN 55035:2017 | Yes | | China GB17625.1:2022 | Yes | | KS C 9832: 2019 and KS C 9835:2019 | Yes | | CISPR 32:2015 | Yes | | VCCI-CISPR 32:2016 | Yes | | Emissions (Australia/NZ) | Yes | | Country Of Approval | | --- | | USA | Yes | | Canada | Yes | | European Union (CE Mark) | Yes | | China CCC | Yes | | South Africa LoA | Yes | | Korea MISP | Yes | | Australia/New Zealand | Yes | | Israel | Yes | | Japan | Yes |