Add Tenable Nessus

Prev Next
  1. Select a receiver.

  2. Click the Properties icon.

  3. From the Receiver Properties window, select Data Sources.

  4. Click Add.

    Option

    Definition

    Data Source Vendor

    Tenable

    Data Source Model

    Nessus

    Data Format

    Default

    Data Retrieval

    SYSLOG (Default)

    Enabled

    Select options for processing events. Some options may not be available for your data source.

    • Parsing - if you want to parse events. Enabling parsing is recommended.

    • Trellix Enterprise Log Manager (ELM) - if you want to log the events on an ELM.

    • Trellix Enterprise Log Search (ELS) - if you want to search event log on an ELS.

    • SNMP Trap - if your environment requires it (this is rare).

    Name

    Enter a name for the data source.

    IP Address/Host Name

    Enter the IP address and host name.

    Note

    Don't use _ (underscore) in a host name field.

    Syslog Relay

    None

    Mask

    0

    Require syslog TLS

    Select to require TLS.

    Port

    Select the port number.

    Support Generic Syslogs

    Do nothing

    Generic Rule Assignment

    Accept default.

    Time Zone

    Select the time zone offset applicable to the data being sent.

  5. (Optional) Click Advanced and configure the settings.

Option

Definition

Device URL

Type the URL address that can be accessed to view event data for this data source (maximum of 512 characters). You can access this URL by clicking the Launch Device URL icon at the bottom of the Event Analysis view.

Vendor, Product, Version

Enter the vendor, product, and version of the device where the Trellix ESM Common Event Format (CEF) forwards events.

Date Order

Select the format for the dates on data sources:

  • Default — Uses the default date order (month before day). When using client data sources, clients using this setting inherit the date order of the parent data source.

  • Month before day — The month goes before the day (04/23/2018).

  • Day before month — The day goes before the month (23/04/2018).

Zone

To assign this data source to a zone, select the zone from the list.

External data source link

Automatically selected when you import events from another receiver. You can clear the checkbox which would remove the distinction of imported data.

For example, you export logs from receiver 1 into receiver 2. The External data source link is applied to the logs being sent so that when logs are imported, Trellix ESM can differentiate the forwarded events.

Export in NitroFile format

Use this option when you are exporting raw data source data.

Data is NitroFile format

Use this option when you are exporting raw data source data.

Note

When you export data sources to a remote file, they are exported in NitroFile format. If you import those files to another Receiver automatically, Data is NitroFile is selected for each of the data sources you are importing. This indicates that the file is in NitroFile format. If you import them manually, you must select this box for each data source.

Validate SHA1 checksum

If the data you are importing is in NitroFile format, select this option if the data source has a checksum file.

Note