The new docs.trellix.com features a modernized UI and AI-powered conversational search. Content is currently available in English, with additional languages launching in early November 2026. We hope you enjoy the updated experience.

Appliance certifications and specifications

Prev Next

Make sure an appliance meets regulatory and environment requirements.

SuperMicro-based platforms

SuperMicro certifications

Trellix 1U

Trellix 2U or 3U

Electromagnetic emissions

FCC Class B, EN 55022 Class B,

EN 61000-3-2/-3-3

CISPR 22 Class B

FCC Class B, EN 55022 Class B,

EN 61000-3-2/-3-3

CISPR 22 Class B

Electromagnetic immunity

EN 55024/CISPR 24,

(EN 61000-4-2, EN 61000-4-3,

EN 61000-4-4, EN 61000-4-5,

EN 61000-4-6, EN 61000-4-8,

EN 61000-4-11) 55024

EN 55024/CISPR 24,

(EN 61000-4-2, EN 61000-4-3,

EN 61000-4--4, EN 61000-4-5,

EN 61000-4-6, EN 61000-4-8,

EN 61000-4-11) 55024

Safety

EN 60950/IEC 60950-Compliant,

UL Listed (USA)

CUL Listed (Canada)

TUV Certified (Germany)

CE Marking (Europe)

EN 60950/IEC 60950-Compliant,

UL Listed (USA)

CUL Listed (Canada)

TUV Certified (Germany)

CE Marking (Europe)



DAS

Trellix DAS certifications

Certification marks

ED, NRTL, RCM, KCC, BSMI, IRAM, EAC

Standards certified to

EN60950-1, EN55032, EN55024

Regions covered

U.S. and Canada, European Union, APAC, LTAM

Other countries with certification

Japan, Israel, South Africa, Ukraine, Morocco



Trellix DAS specifications

DAS-120, DAS-250

Input voltage

100–240 VAC

Input frequency

50/60 Hz

Power supply

800 W X2

Power consumption

DAS-120 - 331 W

DAS-250 - 663 W

Amps (Max)

10@100-127 VAC

5@200-240 VAC

Altitude (Max)

10,000 ft @ 68º F

Temperature (Max)

0º to 35º C (32º to 95º F) operating

–20º to 60º C (-4º to 140º F) non-operating

BTU

DAS-120 - 1331 BTU/HR

DAS-250 - 2661 BTU/HR

Humidity

Operating — 20% to 80% (non-condensing)



Intel-based platforms

Intel-based 1U specifications

Parameter

Limits

Operating temperature

+10° C to +35° C with the maximum rate of change not to exceed 10° C per hour

Non-operating temperature

–40° C to +70°

Non-operating humidity

90%, non-condensing at 35° C

Acoustic noise

Sound Power: 7.0 BA in an idle state at typical office ambient temperature. (23 ± 2 degrees C)

Shock, operating

Half sine, 2-g peak, 11 msec

Shock, unpackaged

Trapezoidal, 25 g, velocity change 136 inches/sec (≧ 40 lbs to > 80 lbs)

Shock, packaged

Non-palletized free fall in height 24 inches (≧40 lbs to > 80 lbs)

Shock, operating

Half sine, 2-g peak, 11 mSec

Vibration, unpackaged

5 Hz to 500 Hz, 2.20 g RMS random

ESD

±12 kV for air discharge and 8 K for contact

System cooling requirement in BTU/Hr

1660 BTU/hour



Intel-based 2U specifications

Parameter

Limits

Temperature

Operating

  • ASHRAE Class A2 — Continuous operation. 10°C to 35°C (50°F to 95°F) with the maximum rate of change not to exceed 10°C per hour.

  • ASHRAE Class A3 — Includes operation up to 40°C for up to 900 hrs per year

  • ASHRAE Class A4 — Includes operation up to 45°C for up to 90 hrs per year

Shipping

–40°C to 70°C (–40°F to 158°F)

Altitude (Operating)

Support operation up to 3050 m with ASHRAE class deratings

Humidity (Shipping)

50% to 90%, non-condensing with a maximum wet bulb of 28°C (at temperatures from 25°C to 35°C)

Shock

Operating

Half sine, 2 g, 11 mSec

Unpackaged

Trapezoidal, 25 g, velocity change is based on packaged weight

Packaged

Product Weight: ≥ 40 to < 80

Non-palletized free fall height = 18 inches

Palletized (single product) free fall height = NA

Vibration

5 Hz to 500 Hz

2.20 g RMS random

Packaged

5 Hz to 500 Hz

1.09 g RMS random

AC-DC

Voltage

90 Hz to 132 V and 180 V to 264 V

Frequency

47 Hz to 63 Hz

Source Interrupt

No loss of data for power line drop-out of 12 mSec

Surge non-operating and operating

Unidirectional