--- title: "Appliance certifications and specifications" slug: "appliance-certifications-and-specifications" tags: ["ESM"] updated: 2026-09-12T21:25:04Z published: 2026-09-12T21:25:04Z canonical: "docs.trellix.com/appliance-certifications-and-specifications" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.trellix.com/llms.txt > Use this file to discover all available pages before exploring further. # Appliance certifications and specifications Make sure an appliance meets regulatory and environment requirements. ### SuperMicro-based platforms SuperMicro certifications | | Trellix 1U | Trellix 2U or 3U | | --- | --- | --- | | Electromagnetic emissions | FCC Class B, EN 55022 Class B, EN 61000-3-2/-3-3 CISPR 22 Class B | FCC Class B, EN 55022 Class B, EN 61000-3-2/-3-3 CISPR 22 Class B | | Electromagnetic immunity | EN 55024/CISPR 24, (EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11) 55024 | EN 55024/CISPR 24, (EN 61000-4-2, EN 61000-4-3, EN 61000-4--4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11) 55024 | | Safety | EN 60950/IEC 60950-Compliant, UL Listed (USA) CUL Listed (Canada) TUV Certified (Germany) CE Marking (Europe) | EN 60950/IEC 60950-Compliant, UL Listed (USA) CUL Listed (Canada) TUV Certified (Germany) CE Marking (Europe) | ### DAS Trellix DAS certifications | Certification marks | ED, NRTL, RCM, KCC, BSMI, IRAM, EAC | | --- | --- | | Standards certified to | EN60950-1, EN55032, EN55024 | | Regions covered | U.S. and Canada, European Union, APAC, LTAM | | Other countries with certification | Japan, Israel, South Africa, Ukraine, Morocco | Trellix DAS specifications | | DAS-120, DAS-250 | | --- | --- | | Input voltage | 100–240 VAC | | Input frequency | 50/60 Hz | | Power supply | 800 W X2 | | Power consumption | DAS-120 - 331 W DAS-250 - 663 W | | Amps (Max) | 10@100-127 VAC 5@200-240 VAC | | Altitude (Max) | 10,000 ft @ 68º F | | Temperature (Max) | 0º to 35º C (32º to 95º F) operating –20º to 60º C (-4º to 140º F) non-operating | | BTU | DAS-120 - 1331 BTU/HR DAS-250 - 2661 BTU/HR | | Humidity | Operating — 20% to 80% (non-condensing) | ### Intel-based platforms Intel-based 1U specifications | Parameter | Limits | | --- | --- | | Operating temperature | +10° C to +35° C with the maximum rate of change not to exceed 10° C per hour | | Non-operating temperature | –40° C to +70° | | Non-operating humidity | 90%, non-condensing at 35° C | | Acoustic noise | Sound Power: 7.0 BA in an idle state at typical office ambient temperature. (23 ± 2 degrees C) | | Shock, operating | Half sine, 2-g peak, 11 msec | | Shock, unpackaged | Trapezoidal, 25 g, velocity change 136 inches/sec (≧ 40 lbs to > 80 lbs) | | Shock, packaged | Non-palletized free fall in height 24 inches (≧40 lbs to > 80 lbs) | | Shock, operating | Half sine, 2-g peak, 11 mSec | | Vibration, unpackaged | 5 Hz to 500 Hz, 2.20 g RMS random | | ESD | ±12 kV for air discharge and 8 K for contact | | System cooling requirement in BTU/Hr | 1660 BTU/hour | Intel-based 2U specifications | Parameter | Limits | | --- | --- | | Temperature | Operating | - ASHRAE Class A2 — Continuous operation. 10°C to 35°C (50°F to 95°F) with the maximum rate of change not to exceed 10°C per hour. - ASHRAE Class A3 — Includes operation up to 40°C for up to 900 hrs per year - ASHRAE Class A4 — Includes operation up to 45°C for up to 90 hrs per year | | | Shipping | –40°C to 70°C (–40°F to 158°F) | | Altitude (Operating) | Support operation up to 3050 m with ASHRAE class deratings | | Humidity (Shipping) | 50% to 90%, non-condensing with a maximum wet bulb of 28°C (at temperatures from 25°C to 35°C) | | Shock | Operating | Half sine, 2 g, 11 mSec | | | Unpackaged | Trapezoidal, 25 g, velocity change is based on packaged weight | | | Packaged | Product Weight: ≥ 40 to < 80 Non-palletized free fall height = 18 inches Palletized (single product) free fall height = NA | | Vibration | | 5 Hz to 500 Hz 2.20 g RMS random | | | Packaged | 5 Hz to 500 Hz 1.09 g RMS random | | AC-DC | Voltage | 90 Hz to 132 V and 180 V to 264 V | | | Frequency | 47 Hz to 63 Hz | | | Source Interrupt | No loss of data for power line drop-out of 12 mSec | | | Surge non-operating and operating | Unidirectional | :