--- title: "Generation 5 LEDs" slug: "generation-5-leds" tags: ["ESM"] updated: 2026-09-12T21:25:18Z published: 2026-09-12T21:25:18Z canonical: "docs.trellix.com/generation-5-leds" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.trellix.com/llms.txt > Use this file to discover all available pages before exploring further. # Generation 5 LEDs The LEDs provide the status information of the server and the activity on its ports. ### Power supply status LED To indicate power supply status, there is a single bi-color LED. The LED operation is defined as: | Power Supply Condition | LED State | | --- | --- | | Output ON and OK | Green | | No AC power to all power supplies | OFF | | AC presents or only 12VSB on (PS off) or PS in Cold redundant state | 1 Hz Blink Green | | AC cord unplugged or AC power lost; with a second power supply in parallel still with AC input power. | Amber | | Power supply warning events where the power supply continues to operate; high temp, high power, high current, slow fan. | 1 Hz Blink Amber | | Power supply critical event causing a shutdown; failure, OCP, OVP, Fan Fail | Amber | | Power supply FW updating | 2 Hz Blink Green | ### External RJ45 NIC Port LED Each ethernet port drives two LEDs on each network interface connector (NIC). The LED on the connector indicates link speed. | LED | Color | LED State | NIC State | | --- | --- | --- | --- | | Left | Green | Off | LAN link not established | | On | LAN link is established | | Blink | Transmit or receive activity | | Right | - | Off | Lowest supported data rate | | Amber | On | Mid-range supported data rate | | Green | On | Highest supported data rate | ### System Status LED Indicate the current health of the server system. | Color | State | Criticality | Description | | --- | --- | --- | --- | | Off | System is not operating | Not ready | - System is turned off (AC or DC). - System is in EuP Lot6 Off Mode. - System is in S5 Soft-Off State. | | Green | Solid on | OK | The system is running (in S0 State) and the status is Healthy. | | Green | 1-Hz blink | Degraded - system is functional, or system is operating in a redundant state but with an impending failure warning | System degraded: Redundancy loss, Fan warning, Non-critical threshold crossed, Power supply predictive failure, and Battery failure. | | Amber | 1-Hz blink | Non-critical - system is operating in a degraded state with an impending failure warning, although still functioning | Non-fatal alarm – system is likely to fail. | | Amber | Solid on | Critical, non-recoverable – System is halted | Fatal alarm – system has failed or shutdown. | ### Drive Activity and Status LED Each drive carrier includes separate LED indicators for drive Activity and drive Status. | Amber | Off | No access and no fault | | --- | --- | --- | | Solid On | Hard Drive Fault has occurred | | Blink | RAID rebuild in progress (1 Hz), Identify (2 Hz) | | | Condition | Drive Type | Behavior | | --- | --- | --- | --- | | Green | Turn on with no drive activity | SAS | LED stays on | | SATA | LED stays off | | Turn on with drive activity | SAS | LED blinks off when processing a command | | SATA | LED blinks on when processing a command | | Turn on and drive spun down | SAS | LED stays off | | SATA | LED stays off | | Turn on and drive spinning up | SAS | LED blinks | | SATA | LED stays off | ### Power or Sleep button Toggles the system turn on and off. This button also functions as a sleep button if enabled by an advanced configuration and power interface (ACPI) compliant operating system. | State | Power Mode | LED | Description | | --- | --- | --- | --- | | Turn off | Non-ACPI | Off | System power is off, and the BIOS has not initialized the chipset. | | Turn on | Non-ACPI | On | System power is on. | | S5 | ACPI | Off | Mechanical is off, and the operating system has not saved any context to the hard disk. | | S0 | ACPI | Steady On | System and the operating system are up and running. | ### BMC Boot or Reset Status LED indicators A baseboard management controller (BMC) boot occurs when AC power is first applied to the system. A BMC reset occurs after a BMC FW update, on receiving a BMC cold command, and on a BMC watchdog initiated reset. | BMC Boot or Reset State | ID LED | Status LED | Description | | --- | --- | --- | --- | | BMC or Video memory test failed | Solid Blue | Solid Amber | Non-Recoverable condition. Contact Trellix support for information about replacing the motherboard. | | Both Universal Bootloader (u-Boot) images bad | Solid Blue | Solid Amber | Non-Recoverable condition. Contact Trellix support for information about replacing the motherboard. | | BMC in u-Boot | Blink Blue 3 Hz | Blink Green 1 Hz | Indicates degraded state, blinking blue indicates u-Boot is running but has not transferred control to BMC Linux. Server is in this state for 6–8 seconds. | | BMC Booting Linux | Solid Blue | Solid Green | Indicates that the control is passed from u-Boot to BMC Linux itself. Server is in this state for 10–20 seconds. | | End of BMC boot or reset process. Normal system operation | Off | Solid Green | Indicates BMC Linux is booted and manageability function is up and running. | :