--- title: "Generation 6 LEDs" slug: "generation-6-leds" tags: ["ESM"] updated: 2026-09-12T21:25:18Z published: 2026-09-12T21:25:18Z canonical: "docs.trellix.com/generation-6-leds" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.trellix.com/llms.txt > Use this file to discover all available pages before exploring further. # Generation 6 LEDs The LEDs provide the status information of the server and the activity on its ports. ### Power supply status LED To indicate power supply status, there is a single bi-color LED. The LED operation is defined as: Trellix ESM power supply indicator light states | Color | State | Status | | --- | --- | --- | | Green | Solid | Power supply is ON | | Blinking | Power supply is plugged in and turned off by the system. | | Amber | Solid | Power supply is plugged in, and is in an abnormal state. The system might need service. | | Blinking | Power supply continues to operate with warning events: - High temperature - High power - High current - Slow fan | | Off | Off | No AC power to all power supplies | ### External RJ45 NIC Port LED Each LAN has one bi-colored LED per port (RJ45 or SFP+) at the bottom of PCB. The LEDs indicates link speed. | LED Color | Description | | --- | --- | | Amber | The data rate is <12Gbps | | Green | The data rate is 12Gbps | ### System Status LED Indicate the current health of the server system. | Color | State | Description | | --- | --- | --- | | Red | Solid on | An overheating condition has occurred | | Red | Blinking at 1Hz | Fan failure, check the inoperative fan | | Red | Blinking at 0.25Hz | Power failure, check the non-operational power supply | | Red | Blinking at 10Hz | CPLD recovery mode error | | Red | blinking at 10Hz and the rear UID LED is blue, blinking at 10Hz | CPLD recovery or update is in progress | | Blue | Solid | Unit ID is activated by the switch | | Blue | Blinking at 1Hz | Unit ID is activated by the BMC | | Blue | Blinking at 2Hz, and BMC Heartbeat LED on the motherboard is green | BMC is resetting | | Blue | Blinking at 4Hz | BMC is resetting factory defaults | | Blue | Blinking at 10Hz | BIOS/BMC is recovering or updating | ### Drive Activity and Status LED Each drive carrier includes separate LED indicators for drive Activity and drive Status. | | Color | State | Behavior of device | | --- | --- | --- | --- | | Status LED | Off | | Idle SATA drive installed | | Blue | Solid on | Idle SAS drive installed | | Blue | Blinking pattern | I/O activity | | | Condition | Drive Type | Behavior | | --- | --- | --- | --- | | Green | Turn on with no drive activity | SAS | LED stays on | | SATA | LED stays off | | Turn on with drive activity | SAS | LED blinks off when processing a command | | SATA | LED blinks on when processing a command | | Turn on and drive spun down | SAS | LED stays off | | SATA | LED stays off | | Turn on and drive spinning up | SAS | LED blinks | | SATA | LED stays off | ### Power button Toggles the system turn on and off. | LED | State | Description | | --- | --- | --- | | Green | Solid | System power is on. | | Green | Blinking at 4Hz | BMC/BIOS checking | | Red | Blinking (2 blinks red) at 4Hz, 1 pause at 2Hz (on-on-off-off) | BMC recovery or update is in progress | | Green | Blinking at 1Hz | BMC/BIOS flash not detected | ### BMC Boot or Reset Status LED indicators A baseboard management controller (BMC) boot occurs when AC power is first applied to the system. A BMC reset occurs after a BMC FW update, on receiving a BMC cold command, and on a BMC watchdog initiated reset. | BMC Boot or Reset State | UID LED | State | Status LED | | --- | --- | --- | --- | | BMC reset | Blue | Blinks at 2Hz | Solid Green | | Restore defaults | Blue | Blinks at 4Hz | Off | | Update | Blue | Blinks at 10Hz | - | :