Log format
Here is the basic logging format listed in the IBM documentation. The advanced logging format and tracing logs are not currently supported. The expected format for this device is:
<timestamp><threadId><shortName><eventType>[className][methodName]<message>
Log sample
This is a sample log from an IBM Websphere Application Server device:
[5/25/15 23:24:25:123 EDT] 00000001 BatchSensorCo I CWLRB5903I: BatchSensorComponent initialized successfully.
Field mapping
This table shows the mapping between the data source and Trellix ESM fields.
Log fields | Trellix ESM fields |
|---|---|
Timestamp | First Time, Last Time |
threadId | External_SessionID |
Shortname | Message (modified by data source rules) |
shortname (hashed) | Signature ID |
eventType | Severity |
Classname | External_Application |
methodName | Method |
Set by DSR | Event Subtype |