--- title: "Restart observation generation for throttling" slug: "restart-observation-generation-for-throttling-1" tags: ["Product Usage", "ACC 8.4.x"] updated: 2026-09-01T13:05:07Z published: 2026-09-01T13:05:07Z canonical: "docs.trellix.com/restart-observation-generation-for-throttling-1" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.trellix.com/llms.txt > Use this file to discover all available pages before exploring further. # Restart observation generation for throttling After you process existing requests and define rules for the accumulated requests, restart observation generation at endpoints. 1. On the ePO - On-prem console, select **Menu** → **Application Control** → **Policy Discovery**. The **Policy Discovery** page displays a message stating that the observation generation has stopped. 2. In the warning message, click **Enable Observation Generation**.