--- title: "Switch to Update mode" slug: "switch-to-update-mode-7" tags: ["Product Usage", "ACC 8.3.x"] updated: 2026-09-09T18:02:39Z published: 2026-09-09T18:02:39Z canonical: "docs.trellix.com/switch-to-update-mode-7" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.trellix.com/llms.txt > Use this file to discover all available pages before exploring further. # Switch to Update mode Switch Application Control to Update mode to perform scheduled or emergency changes in a system. If the product is in Enabled or Disabled mode, perform these steps to switch to Update mode. 1. Run this command at the command prompt. `sadmin bu [workflow-id [comment]]` | Attribute | Description | | --- | --- | | `workflow-id` | Specify a workflow ID for the current Update mode session. This is an identification ID that can be used for a Change Management or Ticketing System. If you don't provide the workflow ID, the workflow ID is set to an automatically generated string, *AUTO_n*, where `n` is a number that is incremented each time an update window is opened. | | `comment` | Specify a comment that describes the current Update mode session. This information can be used for a Change Management or Ticketing System. | 2. If Application Control is in Disabled mode, restart the system. > [!NOTE] > Note > > When using Solidcore client version 6.1.0 or later, restarting the system is not needed to enable the software. When you restart the system, the product is switched to Update mode.