--- title: "The Front View" slug: "the-front-view" tags: ["Endpoint Security (HX)", "Hardware"] updated: 2026-10-19T18:36:54Z published: 2026-10-19T18:36:54Z canonical: "docs.trellix.com/the-front-view" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.trellix.com/llms.txt > Use this file to discover all available pages before exploring further. # The Front View ![HX4600_FrontView.png](https://cdn.us.document360.io/0d453a50-e1da-4d4a-9409-fea7959614d8/Images/Documentation/uuid-d4fd85d5-23fe-544d-0b6b-45a750f3775a.png?sv=2026-02-06&spr=https&st=2026-11-13T01%3A11%3A14Z&se=2026-11-13T02%3A11%3A14Z&sr=c&sp=r&sig=ufKVlxfwcBNx7vMSNPiTXlcE5zEduF%2Fjg6SCpJ8MZT4%3D)![FrontViewLabel](https://cdn.us.document360.io/0d453a50-e1da-4d4a-9409-fea7959614d8/Images/Documentation/uuid-b4d963a5-51af-7a38-0a88-f73953cc7e92(2).png?sv=2026-02-06&spr=https&st=2026-11-13T01%3A11%3A14Z&se=2026-11-13T02%3A11%3A14Z&sr=c&sp=r&sig=ufKVlxfwcBNx7vMSNPiTXlcE5zEduF%2Fjg6SCpJ8MZT4%3D) | 1. Information LED | Alerts operator to several states: | | --- | --- | | Red, solid | An overheat condition has occurred | | Red, blinking at 1 Hz | A fan has failed, check for an inoperative fan | | Red, blinking at 0.25 Hz | A power supply has failed, check for a non-operational power supply | | Red, solid, with Power LED blinking green | Fault detected | | Blue and red, blinking at 10 Hz | Recovery mode | | Blue, solid | UID has been activated locally to locate the server in a rack environment | | Blue, blinking at 1 Hz | UID has been activated using the BMC to locate the server in a rack environment | | Blue, blinking at 2 Hz | BMC is resetting | | Blue, blinking at 4 Hz | BMC is setting factory defaults | | Blue, blinking at 10 Hz with Power LED blinking green | BMC/BIOS firmware is updating | | 2. LAN 2 LED | Indicates network activity on a LAN when flashing. | | | 3. LAN 1 LED | Indicates network activity on a LAN when flashing. | | | 4. HDD LED | Indicates activity on the hard drive when flashing. | | | 5. Power LED | Steady on | Power on | | Blinking at 4 Hz | Checking BIOS/BMC integrity | | Blinking at 4Hz and "i" LED is blue | BIOS firmware updating | | Two blinks at 4 Hz, one pause 2 Hz and "i" LED is blue | BMC firmware updating | | Blinking at 1 Hz and "i" LED is red | Fault detected | | 6. Reset Button | Reboots the system. | | | 7. Power Button | The main power switch applies or removes primary power from the power supply to the server but maintains standby power. Unplug the appliance before servicing. | | | 8. Drive Device LED | Each drive carrier displays two status LEDs on the front of the carrier. | | | 9. Drive Device LED | Each drive carrier displays two status LEDs on the front of the carrier. | | #### Drive Carrier LED Indicators The chassis includes externally accessible SAS/SATA drives. Each drive carrier has two LED indicators: an activity indicator and a status indicator. | LED Type | Color | Blinking Pattern | Meaning of Blinking Pattern | | --- | --- | --- | --- | | Activity LED | Blue | Solid On | Idle SAS/NVMe drive installed. | | Blinking | I/O activity. | | Off | Idle SATA drive installed. | | Status LED | Red | Solid On | Failure of drive with RSTe support. | | Blinking at 1 Hz | Rebuild drive with RSTe support. | | On for five seconds, then off | Power on for drive with RSTe support. | | Blinking at 4 Hz | Identify drive with RSTe support. | | Blinking with two blinks and one stop at 1 Hz | Hot spare for drive with RSTe support | | Green | Solid Green LED | Safe to remove NVMe device. | | Amber | Blinking at 1 Hz | Do not remove NVMe device. | #### Chassis 1. **Disk Drive Carrier:** Each carrier can house a hot-swappable disk drive. A drive slot map displays the disk slot numbers on top of the appliance. 2. **Handle Release:** Press this tab to release the handle. Use the handle to pull the disk drive carrier from the chassis. :