# 3. Configure Active Fail-Open chassis parameters
## Before you begin
To proceed with the setup, you will require:
- One RJ-45 RS-232 cable for console connection.
- One RJ-45 cable for network management connection.
Perform the following steps to configure the parameters of an Active Fail-Open chassis.
## Task
1. Connect the applicable cable to the Active Fail-Open chassis.
2. Connect the RJ-45 RS232 cable to a computer which runs a terminal emulation software such as HyperTerminal or PuTTY.
3. Launch the terminal emulation software and set the following communication parameters:
- Baud rate: 115200
- Data bits: 8
- No parity
- Stop bits: 1
- No flow control
4. Turn on the Active Fail-Open chassis.
The CLI banner and login prompt are displayed.
5. At the login prompt, type the username and password, and press
**Enter**.
| For Active Fail-Open switches 16 and 17 |
| --- |
| Username | Trellix00 |
| Password | Trellix00 |
The Active Fail-Open chassis CLI prompt is displayed.
6. Type the following commands for the Active Fail-Open modules 28 and 29.
- enable
- configure
- management eth-if ip x.x.x.x
- management eth-if ip-mask y.y.y.y
- management eth-if default-gateway z.z.z.z
- write memory
> [!NOTE]
> Note
>
> Reboot of the system is not required.
For more information on the CLI commands, see Trellix Intrusion Prevention System 100 Gigabit Modular Active Fail Open Bypass Kit Guide.