The new docs.trellix.com features a modernized UI and AI-powered conversational search. Content is currently available in English, with additional languages launching in early November 2026. We hope you enjoy the updated experience.

3. Configure Active Fail-Open chassis parameters

Prev Next

Prerequisites:

To proceed with the setup, you require:

  • One RJ-45 RS-232 cable for console connection.

  • One RJ-45 cable for network management connection.

Perform the following steps to configure the parameters of an Active Fail-Open chassis.

  1. Connect the applicable cable to the 40G Active Fail-Open chassis.

  2. Connect the RJ-45 RS232 cable to a computer which runs a terminal emulation software such as HyperTerminal or PuTTY.

  3. Launch the terminal emulation software and set the following communication parameters:

    • Baud rate: 115200

    • Data bits: 8

    • No parity

    • Stop bits: 1

    • No flow control

  4. Turn on the Active Fail-Open chassis.

    The CLI banner and login prompt are displayed.

  5. At the login prompt, type the username and password, and press Enter.

    Username and password for both sets of Active Fail-Open modules

    For Active Fail-Open switches 12 thru 14

    Username

    Trellix00

    Password

    Trellix00



    The Active Fail-Open chassis CLI prompt is displayed.

  6. Use the following commands for the Active Fail-Open modules 12 thru 14.

    CLI commands for Active Fail-Open modules 12 thru 14

    Command

    Description

    get_gateway

    Displays default gateway address.

    get_ip

    Displays Active Fail-Open chassis IPv4 address.

    get_netmask

    Displays Active Fail-Open chassis network mask.

    set_gateway xxx.xxx.xxx.xxx

    Configures default gateway IPv4 address.

    Reboot the Active Fail-Open chassis for the new gateway IPv4 address to take effect.

    set_ip xxx.xxx.xxx.xxx

    Configures Active Fail-Open chassis IPv4 address.

    Reboot the Active Fail-Open chassis for the new IPv4 address to take effect.

    set_netmask xxx.xxx.xxx.xxx

    Configures Active Fail-Open chassis network mask.

    Reboot the Active Fail-Open chassis for the new network mask to take effect.

    get_stat

    Displays the device statistics

    stop_all_sessions

    Stops all opened sessions



    For more information on the CLI commands, see Trellix Intrusion Prevention System 10G/40G Active Fail-Open Bypass Kit Guide.