4. Configure notification by SNMP traps

Prev Next

Before you begin

  • To configure SNMP traps, you require a server that acts as an SNMP server. The SNMP server can be any Windows or Linux system installed with a MIB browser such as iReasoning.  

    To view the requirements and download a copy of iReasoning MIB browser, follow the link:   https://ireasoning.com/mibbrowser.html.  

  • Make sure the IP address of the 40G Active Fail-Open chassis can be reached within the network.  

  • Make sure the SNMP server and the 40G Active Fail-Open chassis are able to communicate.  

  • In addition, you need to obtain MIB files to decode alert codes sent by the 10G/40G Active Fail-Open modules. These files are specific to the 10G/40G Active Fail-Open modules and can be obtained by clicking this link:   KB86247.  

Task

  1. Connect an RJ-45 cable to the Management port at the front of the 40G Active Fail-Open chassis.    

  2. Connect the other end to a network device so that the SNMP server is reachable through the network.    

  3. Copy the MIB files of an Active Fail-Open module to a suitable location on the SNMP server.    

    For example, an SNMP trap is generated when one of the following events occur:  

    • Bypass state changes  

    • Any of the port link status changes  

    • Either power supply state changes or any other trap defined under   Snmp → SNMP trap control in the web interface.  

  4. Set up the 40G Active Fail-Open chassis IP address, network mask, and SNMP manager IP address using the commands provided in the section   3. Configure Active Fail-Open chassis parameters.    

  5. Make sure the SNMP manager and Active Fail-Open chassis are able to communicate.    

Results

Configuration of SNMP traps is complete when a trap appears in the MIB browser.