4. (Optional) Configure notification by SNMP traps

Prev Next

Before you begin

  • To configure SNMP traps, you will require a server that acts as an SNMP server. The SNMP server can be any Windows or Linux system installed with a MIB browser, such as iReasoning. To view requirements and download a copy of iReasoning MIB browser, follow the link:https://ireasoning.com/mibbrowser.html.  

  • Make sure your fail-open switch IP address can be reached within the network.  

  • Make sure your SNMP server and fail-open switch are able to communicate.  

  • In addition, you will need to obtain MIB files to decode alert codes sent by the fail-open switch. These files are specific to the fail-open switch and can be obtained by clicking this link:   KB86247.  

  • You will require the RJ-45 cable.  

Task

  1. Connect an RJ-45 cable to the Management Port at the front of the fail-open switch.    

  2. Connect the other end to a network device so that the SNMP server is reachable through the network.    

  3. Copy the fail-open switch MIB files to a suitable location on the SNMP server.    

    For example, an SNMP trap is generated when one of the following events occur:  

    • Bypass state changes  

    • Any port link status changes  

    • Either power supply state changes  

  4. Set up the fail-open switch IP address, network mask, and SNMP manager IP address using the commands provided in the section   Configure the fail-open switch parameters.    

  5. Make sure the SNMP manager and fail-open switch are able to communicate.    

Results

Configuration of SNMP traps is complete when you can see a trap appear in the MIB browser.