--- title: "5. Deploy a Sensor in inline fail-open mode" slug: "5-deploy-a-sensor-in-inline-fail-open-mode" tags: ["Product Usage", "IPS 10.1.10"] updated: 2026-10-05T15:39:53Z published: 2026-10-05T15:39:53Z canonical: "docs.trellix.com/5-deploy-a-sensor-in-inline-fail-open-mode" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.trellix.com/llms.txt > Use this file to discover all available pages before exploring further. # 5. Deploy a Sensor in inline fail-open mode ## Before you begin A Sensor which - Is set up and has established trust with a Manager - Has a free port pair that can be deployed in inline fail-open configuration - SFPs or XFPs, depending on the Sensor model and fail-open switch model > [!NOTE] > Note > > The steps below assume you are using an M-Series Sensor when selecting ports. Configuration of a port pair for inline fail-open active operation ![](https://cdn.us.document360.io/0d453a50-e1da-4d4a-9409-fea7959614d8/Images/Documentation/GUID-FC233FEE-DAC4-4D4A-AAA7-BB7BC90F44F1-low.png?sv=2026-02-06&spr=https&st=2026-11-20T10%3A28%3A25Z&se=2026-11-20T11%3A28%3A25Z&sr=c&sp=r&sig=Z6cJn4MqiJ8OEwfgqHhuvAPRHcq6Nlc33L1vib3D2ds%3D) To configure a fail-open switch you must configure the port pair to operate as an inline fail-open port. ## Task 1. After cabling the Sensor and the fail-open switch, log on to your Manager. 2. Go to **Devices** → **** → **Devices** → **** → **Setup** → **Physical Ports**. 3. Double-click port **1A**. A configuration window appears on the right side of the window. 4. Click the **State** drop-down and select **Enabled**. This enables port **1A-1B**. 5. Select the **Auto Negotiate** checkbox and make sure the **Speed (Duplex)** is set to **1 Gbps (Full)**. In case of the 4-port RJ-45 module, the maximum **Speed (duplex)** can be set to 10 Gbps (Full). When you set the **Speed (duplex)** to 10 Gbps (Full), the link will come up only when the **Auto Negotiate** option is ON. To this effect, the **Auto Negotiate** checkbox automatically gets selected and disabling the **Auto Negotiate** option is not allowed. 6. Click the **Mode** drop-down and select **Inline Fail Open – Active**. This means port pair 1A-1B is now configured for inline fail-open. 7. Click the **Placement** drop-down and select **Inside Network** or **Outside Network**, depending on how you want to configure your ports. **Placement** refers to the area of the network which that individual port is connected. 8. Click the **Response Port** drop-down and select the right port that you want to assign. For an inline fail-open or fail-closed setup, you can configure the same port to be the response port. 9. Click **Save**. ## Results If traffic is passing through the ports, you will notice the port link status changes to **Up** and goes green.