--- title: "6. Deploy a Sensor in inline Active Fail-Open mode" slug: "6-deploy-a-sensor-in-inline-active-fail-open-mode-10" tags: ["Product Usage", "IPS 11.1.x"] updated: 2026-11-19T12:30:59Z published: 2026-11-19T12:30:59Z canonical: "docs.trellix.com/6-deploy-a-sensor-in-inline-active-fail-open-mode-10" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.trellix.com/llms.txt > Use this file to discover all available pages before exploring further. # 6. Deploy a Sensor in inline Active Fail-Open mode **Prerequisites:** - The Sensor must be set up and have established trust with a Manager server. - The Sensor has a free port pair which can be deployed in inline Active Fail-Open mode. - It is assumed that you have inserted necessary transceiver modules into the Sensor if you have completed cabling the Sensor and Active Fail-Open module. When you set up a Sensor for the first time, its ports are disabled by default. The Sensor ports must be manually configured for inline Active Fail-Open operation. **Steps:** 1. In the Manager, go to **Devices** → **** → **Devices** → **** → **Setup** → **Physical Ports**. 2. Double-click port one of the configurable ports, say **1/1** (Gx/1). A configuration panel appears on the right side of the window. 3. Click the **State** drop-down and select **Enabled**. This will impact the port 2/2 (Gx/2) as well. So, ports **2/1-2/2** (Gx/1-Gx/2) are enabled. 4. Click the **Certification** drop-down and select an option depending on your requirement. > [!NOTE] > Note > > Based on the I/O module and port selected, you may be required to select the **Auto Negotiate** checkbox and set the speed under **Maximum Negotiable Speed (Duplex)**. For certain ports, the speed is automatically selected and you will not be able to edit it. 5. Select **FEC** checkbox if you want to enable Forward Error Connection. > [!NOTE] > Note > > FEC should only be enabled when needed, and the device to which this port is connected must have FEC enabled too. 6. Under **Mode**, select **Inline Active Fail-Open – Active** from the drop-down list. 7. Under **Placement**, select **Inside Network** or **Outside Network** from the drop-down list, depending on how you want to configure your ports. ![GUID-EFEB2BFD-DD8C-4785-BD94-CCE645B3D5F6-low.png](https://cdn.us.document360.io/0d453a50-e1da-4d4a-9409-fea7959614d8/Images/Documentation/uuid-0f0e8a0d-e215-874c-eefc-87bfcab41561(8).png?sv=2026-02-06&spr=https&st=2026-11-20T13%3A50%3A50Z&se=2026-11-20T14%3A50%3A50Z&sr=c&sp=r&sig=Z9qQ6We6D%2B9IAvoyE9AiKyxXUCHaY%2BFq5F%2B7tsOaGqk%3D) 8. Click **Save**. > [!NOTE] > Note > > An **Alert!** pop-up displays stating the changes made on port x/1 impacts x/2 as well. Click **OK**. The Sensor and Active Fail-Open module are set up. When traffic passes through the ports, the port link status changes to **Up** and turns green.