# About Sensor port configuration
Before you configure the Sensor ports, you must have installed the Sensor and added to the Manager interface.
**Configure inline mode for a single Sensor**
This section contains recommendations for deploying a single Sensor in inline mode.
> [!NOTE]
> Note
>
> Configuration for a fail-open kit is described in the fail-open kit documentation. For example, to configure the Sensor to work with the copper fail-open kit, see the Trellix Intrusion Prevention System Fail-Open Kit Product Guide.
1. In the Manager interface, select **Devices** → **** → **Devices** → **** → **Setup** → **Physical Ports**.
2. Double-click on a numbered port (for example, 3/1) from **Monitoring Ports**.
**Monitoring Port Details** panel displays current port settings.
**Verifying ports for inline fail-open mode**.png?sv=2026-02-06&spr=https&st=2026-11-20T11%3A54%3A35Z&se=2026-11-20T12%3A54%3A35Z&sr=c&sp=r&sig=91AeeAbRZEN4MWwP36JMj0NAy7gGtNKWwMI1m0N%2FItM%3D)
3. Set the Administrative **State** to **Disable** (off).
4. Select the other port (for example, 3/2) and set the Administrative **State** to **Disable** (off).
5. Now select the aforesaid port (port 3/1) and select the **Auto Negotiate** checkbox.
6. Select the port **Speed**.
7. Do one of the following:
- For inline fail-closed operation, select **Inline Fail Closed** as the operating Mode.
- For inline fail-open operation, select **Inline Fail Open** or **Inline Fail Open - Active** as the operating Mode. Confirm (**Yes**) that you have already connected a fail-open kit. However, if your Sensor supports in-built fail-open on that port, you might not require a fail-open kit.
> [!NOTE]
> Note
>
> **Inline Fail Open** indicates in-built passive fail-open which is supported on different Sensors differently.
8. Select the area of your network to which the current port is connected: **Inside** (traffic generated internally, destined for the external network) or **Outside** (traffic generated externally, destined for the internal network).
9. Set the Administrative **State** to **Enable** (on).
10. Click **Save**.