The new docs.trellix.com features a modernized UI and AI-powered conversational search. Content is currently available in English, with additional languages expected in early November 2026. We hope you enjoy the updated experience.

Access the Active Fail-Open module web interface

Prev Next

If you have configured an IPv4 address for your Active Fail-Open chassis, you have the option to manage it through a web-interface.

Task

  1. To access the Active Fail-Open module web interface, enter the IPv4 address of the Active Fail-Open chassis which you have configured through https://x.x.x.x.
    The Active Fail-Open module web interface appears on the login screen.
  2. To login, enter the default username and password, Trellix00 and Trellix00.
  3. Go to, Status → Module <number>.

Results

Under Segment Status, you can view the present settings configured in the Active Fail-Open module. Configuration of necessary settings is explained in the relevant sections.

Callout Description
1 Active State:
  • Inline - Sensor receives traffic and the fail-open module is operating in normal mode
  • Bypass - Sensor does not receive traffic and the fail-open module is not operating in inline mode
  • Tap - Fail-open module functioning like a TAP kit
2 Passive State:
  • Inline - Fail-open module operating in normal mode
  • Bypass - Sensor does not receive traffic and the fail-open module is not operating in inline mode
3 Application State:
  • Active - Monitoring ports are up and the heartbeat packets are received
  • Fail - Monitoring ports are up, but the heartbeat packets are not received