If you have configured an IPv4 address for your Active Fail-Open chassis, you have the option to manage it through a web-interface.
Task
To access the Active Fail-Open module web interface, enter the IPv4 address of the Active Fail-Open chassis which you have configured through
https://x.x.x.x.
The Active Fail-Open module web interface appears on the login screen.
To login, enter the default username and password,
Trellix00 and
Trellix00.
Go to,
Status → Module <number>.
Results
Under
Segment Status, you can view the present settings configured in the Active Fail-Open module. Configuration of necessary settings is explained in the relevant sections.
Callout
Description
1
Active State:
Inline - Sensor receives traffic and the fail-open module is operating in normal mode
Bypass - Sensor does not receive traffic and the fail-open module is not operating in inline mode
Tap - Fail-open module functioning like a TAP kit
2
Passive State:
Inline - Fail-open module operating in normal mode
Bypass - Sensor does not receive traffic and the fail-open module is not operating in inline mode
3
Application State:
Active - Monitoring ports are up and the heartbeat packets are received
Fail - Monitoring ports are up, but the heartbeat packets are not received