--- title: "Add a Sensor to the Manager" slug: "add-a-sensor-to-the-manager-5" tags: ["Install and Get Started", "IPS 11.1.x"] updated: 2026-11-19T12:54:18Z published: 2026-11-19T12:54:18Z canonical: "docs.trellix.com/add-a-sensor-to-the-manager-5" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.trellix.com/llms.txt > Use this file to discover all available pages before exploring further. # Add a Sensor to the Manager To add a Sensor, perform the following steps: **Steps:** 1. Go to **Devices** → **** → **Global** → **Device Manager**. The **Device Manager** page is displayed. 2. Select the **Sensors** tab and click ![GUID-E7BA235E-C8E9-494B-A481-32F301FEAAB8-low.png](https://cdn.us.document360.io/0d453a50-e1da-4d4a-9409-fea7959614d8/Images/Documentation/uuid-72053356-4c05-0f24-325f-27e024879a39(3).png?sv=2026-02-06&spr=https&st=2026-11-20T07%3A40%3A07Z&se=2026-11-20T08%3A40%3A07Z&sr=c&sp=r&sig=y%2BdPdMGdjlFRMBjf8Cu%2FlZrGYnCumgwhy23xtJUZzMU%3D). The **Add Device - Step 1 of 2** panel is displayed. 3. Enter relevant details in the **Add Device - Step 1 of 2** panel. 1. Enter the **Name** of the device. The Sensor name must begin with a letter. The maximum length of the name is 25 characters. 2. Enter the **Shared Secret**. The shared secret must be a minimum of 8 characters and maximum of 25 characters in length. The key cannot start with an exclamation mark nor can have any spaces. The parameters that you can use to define the key are: - 26 alphabets: upper and lowercase (a,b,c,...z and A, B, C,...Z) - 10 digits: 0 1 2 3 4 5 6 7 8 9 - 31 symbols: ~ ` ! @ # $ % ^ & * ( ) _ + - = [ ] { } \ | ; : " ' , . < / > [!NOTE] > Note > > The Sensor name and shared secret key that you enter in the Manager must be identical to the shared secret that you will later enter during physical installation/initialization of the Sensor (using CLI). If not, the Sensor will not be able to register itself with Manager. 3. Enter the **Confirm Shared Secret**. 4. Select the required **Device Type** as **IPS Sensor** or **NTBA Appliance**. 4. Select the **Deployment Mode** as either **Direct** or **Indirect** from the drop-down. In **Direct** mode, pending changes are delivered directly from the Manager to Sensor. It is the recommended mode. In **Indirect** mode, when trust is established between the Manager and the Sensor, the initial configuration update from Manager to Sensor will be stopped. You can toggle between **Direct** and **Indirect** modes in the Manager by navigating to **Devices** → **** → **Devices** → **** → **Summary**. In the **Sync** monitor, select **Direct** or **Indirect** against **Sync Mode** and click **Save**. The Sensor status will be shown as **good** in the CLI only after successful configuration update by enabling the **Direct** mode. 5. If required, enter the **Contact Information**, **Location**, and **Comment** details. 6. Click **Save.** An **Information** dialog box is displayed to confirm the addition of Sensor. Click **OK**. The new Sensor is displayed in the **Sensors** tab of **Device Manager** page.