The new docs.trellix.com features a modernized UI and AI-powered conversational search. Content is currently available in English, with additional languages launching in early November 2026. We hope you enjoy the updated experience.

Adding an SNMP trap sink using the CLI

Prev Next

You can use the CLI to to send notifications to one or more SNMP trap sink servers.

Prerequisites

  • Admin or Operator access to the Malware Analysis appliance.

To add an SNMP Trap Sink:
  1. Enable the CLI configuration mode:

    hostname > enable
    hostname # configure terminal
  2. Enable SNMP notifications:

    hostname (config) # fenotify snmp enable
  3. Specify the name of the SNMP server (for example, NX7400) for SNMP notifications:

    hostname (config) # fenotify snmp trap-sink <sink name>
  4. Specify which servers will receive SNMP notifications (one server per command):

    hostname (config) # fenotify snmp trap-sink <sink name> enable
  5. Specify the IP address or DNS address of the SNMP server to receive the notifications:

    hostname (config) # fenotify snmp trap-sink <sink name> address <ip address>
  6. Save the configuration:

    hostname (config) # write memory