--- title: "Appendix 1: System Specifications" slug: "appendix-1-system-specifications-7" tags: ["Network Security (NX)", "Hardware"] updated: 2026-10-19T20:01:18Z published: 2026-10-19T20:01:18Z canonical: "docs.trellix.com/appendix-1-system-specifications-7" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.trellix.com/llms.txt > Use this file to discover all available pages before exploring further. # Appendix 1: System Specifications The table below provides the technical specifications for the Trellix NX 3600 | Component | NX 3600 Specifications | | --- | --- | | Form Factor | 1U Chassis | | Weight of Appliance | 30.3 lbs | | Weight of Packaged Appliance | 37.3 lbs | | Dimensions (W x D x H) | 17.2in (437 mm) X 19.98in (507 mm)X1.7in (43 mm) | | Enclosure | 1 RU, fits 19-inch Rack | | Management Interfaces | (2) 10/100/1000BASE-T Ports | | Monitoring Interfaces | (4) 10/100/1000BASE-T Ports (4) 1G/10G SFP+ Ports | | Memory | 64 GB (2 x 32 GB) | | Drive Capacity | (2) 4 TB HDD, RAID 1, 3.5 inch, FRU | | AC Power Supply | Redundant (1+1), FRU, 400W with Input 1100-240VAC / 6.0 – 3.0A \| 200-240VDC / 3.4- 3.2A, 50-60 Hz IEC60320- C14 inlet | | Maximum Power Consumption | 300 W | | Operating Temperature | 5°C - 35°C (41°F - 95°F) | | Maximum Thermal Dissipation | 1024 Btu/hr | | Relative Humidity | Operational standard: 90% RH Non-operational standard: 95% RH ### Note The appliance box can work under 90% RH, and can also be stored (powered off) at 95% RH for a short period of time. It is not recommended to store any electronics in high humidity places for an extended period of time. | :