--- title: "Cable the Sensors in a stack for high availability" slug: "cable-the-sensors-in-a-stack-for-high-availability" tags: ["Hardware"] updated: 2026-09-17T10:17:59Z published: 2026-09-17T10:17:59Z canonical: "docs.trellix.com/cable-the-sensors-in-a-stack-for-high-availability" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.trellix.com/llms.txt > Use this file to discover all available pages before exploring further. # Cable the Sensors in a stack for high availability This procedure describes how to cable Sensors in a stack for high availability. 1. Plug the QSFP28 Direct Attach Copper (DAC) cable into port **G0/3** of the first Sensor in the active stack. 2. Connect the other end of the cable into the corresponding port labeled **G0/3** of the first Sensor in the standby stack. 3. Repeat steps 1 and 2 for the other Sensors in the active and standby stack. ![NS9600-cabling-the-sensors-in-a-stack-for-high-availability-nonPFO.jpg](https://cdn.us.document360.io/0d453a50-e1da-4d4a-9409-fea7959614d8/Images/Documentation/uuid-cf6f31bb-3890-102a-5c75-9707a5c4b009.jpg?sv=2026-02-06&spr=https&st=2026-11-20T08%3A30%3A05Z&se=2026-11-20T09%3A30%3A05Z&sr=c&sp=r&sig=HA33MuMmNEpYFRA6eSzf8p9kXXPbAi017jJVS2YKwf0%3D) 4. On the rear panel of each NS9600 Sensor, plug a RJ-45 cable in the Management port (labeled MGMT). 5. Plug the other end of the cable into the network device connected to your Manager server. 6. Create a failover pair using the **HA Pairs** tab in **Devices** → **** → **Global** → **Device Manager** page in the Manager.