--- title: "Change a monitoring port from SPAN mode to TAP or Inline mode (and vice versa)" slug: "change-a-monitoring-port-from-span-mode-to-tap-or-inline-mode-and-vice-versa-2" tags: ["Product Usage", "IPS 11.1.x"] updated: 2026-11-19T12:26:40Z published: 2026-11-19T12:26:40Z canonical: "docs.trellix.com/change-a-monitoring-port-from-span-mode-to-tap-or-inline-mode-and-vice-versa-2" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.trellix.com/llms.txt > Use this file to discover all available pages before exploring further. # Change a monitoring port from SPAN mode to TAP or Inline mode (and vice versa) You must disable both ports required for port pair operation when changing the operating Mode from single port (SPAN or Hub) Mode to a port pair (Tap or Inline) mode. Device monitoring ports are configured by default to operate in SPAN or Hub mode. 1. Go to **Devices** → **** → **Devices** → **** → **Setup** → **Physical Ports**. 2. Double-click on the row of the port to be configured. The **Monitoring Port Details** panel is displayed on the right side. 3. Select **Disabled** from the **State** drop-down list. 4. Click **Save**. 5. Select the peer port (for example, G0/2). 6. Select **Disabled** at the **State** drop-down list. 7. Select **Tap** or **Inline Fail Open** mode as the **Mode**. > [!NOTE] > Note > > To configure from port pair mode to single port mode, select **SPAN or Hub** as the **Mode**. 8. Click **Enabled** at **State**. 9. Configure your port settings (port speed or Trellix certification, duplex, response port usage). 10. Click **Save**. 11. Select port G0/1 to verify the **State** reads **Enabled** and the **Mode** matches your new setting. 12. Click **Save**.