--- title: "Check your shipment" slug: "check-your-shipment" updated: 2026-09-08T19:57:04Z published: 2026-09-08T19:57:04Z canonical: "docs.trellix.com/check-your-shipment" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.trellix.com/llms.txt > Use this file to discover all available pages before exploring further. # Check your shipment Each product ships with all the items needed to install the appliance on a network. ##### To verify that you received all the necessary items, verify that you have received the following: - Intelligent Sandbox Appliance - Accessories itemized on the Content Sheet - Set of tool-less slide rails - Front bezel with key - Country or region specific power cords ##### Intelligent Sandbox Appliance front and back panels Figure 1. ATD-3000 and ATD-6000 front panel | ![ATD-3000 and ATD-6000 front panel](https://cdn.us.document360.io/0d453a50-e1da-4d4a-9409-fea7959614d8/Images/Documentation/uuid-e73df3ed-2343-f15f-c647-a7250fa88d28.png?sv=2026-02-06&spr=https&st=2026-11-22T16%3A18%3A47Z&se=2026-11-22T17%3A18%3A47Z&sr=c&sp=r&sig=NkjDEvuQOvA28g8N7DJFD1P2Rh%2FWdx4Aw5O2%2FygH%2BAE%3D) | | --- | | Label | Description | | --- | --- | | 1 | System ID button with integrated indicator light | | 2 | NMI button (recessed, tool required for use) | | 3 | NIC 1 activity indicator light | | 4 | - ATD-3000: NIC 3 activity indicator light - ATD-6000: Not used | | 5 | System cold reset button | | 6 | System status indicator light | | 7 | Power button with integrated indicator light | | 8 | Hard drive activity indicator light | | 9 | - ATD-3000: NIC 4 activity indicator light - ATD-6000: Not used | | 10 | NIC 2 activity indicator light | Figure 2. ATD-3000 Appliance back panel | ![ATD-3000 Appliance back panel](https://cdn.us.document360.io/0d453a50-e1da-4d4a-9409-fea7959614d8/Images/Documentation/uuid-a313bdb2-d857-efd5-d7f8-4072e3cefb5a.png?sv=2026-02-06&spr=https&st=2026-11-22T16%3A18%3A47Z&se=2026-11-22T17%3A18%3A47Z&sr=c&sp=r&sig=NkjDEvuQOvA28g8N7DJFD1P2Rh%2FWdx4Aw5O2%2FygH%2BAE%3D) | | --- | | Label | Description | | --- | --- | | 1 | Power supply module 1 | | 2 | Power supply module 2 | | 3 | Management port (NIC 1). This is the eth-0 interface. The **`set appliance`** and **`set mgmtport`** commands apply to this interface. For example, when you use the **`set appliance ip`** command, the corresponding IP address is assigned to this interface. | | 4 | NIC 2. This is the eth-1 interface. This interface is disabled by default. - To enable or disable this interface, use the **`set intfport`** command. For example, **`set intfport 1 enable`** - To assign the IP details to this interface use **`set intfport <eth 1, 2, or 3> ip <IPv4 address> <subnet mask>`** For example, **`set intfport 1 ip 10.10.10.10 255.255.255.0`** - You cannot assign the default gateway to this port. However, you can configure a route on this interface to route the traffic to the desired gateway. To configure a route, use **`route add network <IPv4 subnet> netmask <netmask> gateway <IPv4 address> intfport 1`** For example, **`route add network 10.10.10.0 netmask 255.255.255.0 gateway 10.10.10.1 intfport 1`**. This command routes all traffic from the 10.10.10.0 command to 10.10.10.1 through NIC 2 (eth-1). | | 5 | NIC 3. This is the eth-2 interface. The note described for NIC 2 applies to this interface as well. | | 6 | NIC 4. This is the eth-3 interface. The note described for NIC 2 applies to this interface as well. | | 7 | Video connector | | 8 | RJ45 serial-A port | | 9 | USB ports | | 10 | RMM4 NIC port | | 11 | I/O module ports/connectors (not used) | | 12 | Add-in adapter slots from riser card 1 and riser card 2 | Figure 3. ATD-6000 Appliance back panel | ![ATD-6000 Appliance back panel](https://cdn.us.document360.io/0d453a50-e1da-4d4a-9409-fea7959614d8/Images/Documentation/uuid-f12032fe-fbb7-a4c4-42fc-bd113f699ed6.png?sv=2026-02-06&spr=https&st=2026-11-22T16%3A18%3A47Z&se=2026-11-22T17%3A18%3A47Z&sr=c&sp=r&sig=NkjDEvuQOvA28g8N7DJFD1P2Rh%2FWdx4Aw5O2%2FygH%2BAE%3D) | | --- | | Label | Description | | --- | --- | | 1 | USB ports | | 2 | USB ports | | 3 | Management port. This is the eth-0 interface. The **`set appliance`** and **`set mgmtport`** commands apply to this interface. For example, when you use the **`set appliance ip`** command, the corresponding IP address is assigned to this interface. | | 4 | Additional I/O module ports/connectors. These are the eth-1, eth-2, and eth-3 interfaces respectively. These interfaces are disabled by default. - To enable or disable an interface, use the **`set intfport`** command. For example, **`set intfport 1 enable`** to enable eth-1. - To assign the IP details to an interface use **`set intfport <eth 1, 2, or 3> ip <IPv4 address> <subnet mask>`** For example, **`set intfport 1 ip 10.10.10.10 255.255.255.0`** - You cannot assign the default gateway to this port. However, you can configure a route on this interface to route the traffic to the desired gateway. To configure a route, use **`route add network <IPv4 subnet> netmask <netmask> gateway <IPv4 address> intfport 1`** For example, **`route add network 10.10.10.0 netmask 255.255.255.0 gateway 10.10.10.1 intfport 1`**. This command routes all traffic from the 10.10.10.0 command to 10.10.10.1 through eth-1. | | 5 | Video connector | | 6 | NIC 1 (currently not used) | | 7 | NIC 2 (currently not used) | | 8 | RJ45 serial-A port | | 9 | I/O module ports/connectors (not used) | | 10 | Add-in adapter slots from riser card | | 11 | RMM4 NIC port | | 12 | Power supply module 2 | | 13 | Power supply module 1 | | 14 | Add-in adapter slots from riser card | ##### Figure 4. ATD-3100, and ATD-6100 Appliance Front panel | ![ATD-3100, and ATD-6100 Appliance Front panel](https://cdn.us.document360.io/0d453a50-e1da-4d4a-9409-fea7959614d8/Images/Documentation/uuid-9376fa0c-d623-fca1-8d2c-3fe411a2a26a.png?sv=2026-02-06&spr=https&st=2026-11-22T16%3A18%3A47Z&se=2026-11-22T17%3A18%3A47Z&sr=c&sp=r&sig=NkjDEvuQOvA28g8N7DJFD1P2Rh%2FWdx4Aw5O2%2FygH%2BAE%3D) | | --- | | Label | Description | | --- | --- | | 1 | System ID button with integrated indicator light | | 2 | NMI button (recessed, tool required for use) | | 3 | INTF2 activity indicator light | | 4 | System status indicator light | | 5 | Power button with integrated indicator light | | 6 | Hard drive activity indicator light | | 7 | System cold reset button | | 8 | INTF3 activity indicator light | Figure 5. ATD-3100, and ATD-6100 Appliance back panel | ![ATD-3100, and ATD-6100 Appliance back panel](https://cdn.us.document360.io/0d453a50-e1da-4d4a-9409-fea7959614d8/Images/Documentation/uuid-930c629f-2dca-7802-ab43-5a32c49cf493.png?sv=2026-02-06&spr=https&st=2026-11-22T16%3A18%3A47Z&se=2026-11-22T17%3A18%3A47Z&sr=c&sp=r&sig=NkjDEvuQOvA28g8N7DJFD1P2Rh%2FWdx4Aw5O2%2FygH%2BAE%3D) | | --- | | Label | Interface port | | --- | --- | | 1 | Power supply module 1 | | 2 | Power supply module 2 | | 3 | Ethernet interface 2 (intf2) | | 4 | Ethernet interface 3 (intf3) | | 5 | VGA connector | | 6 | Serial console interface | | 7 | USB 3.0 ports | | 8 | BMC port (RMM) | | 9 | Ethernet interface 0 (ATD Management Interface) | | 10 | Ethernet interface 1 (intf1) | Figure 6. ATD- 3200, ATD-6200 Appliance Front panel | ![ATD- 3200, ATD-6200 Appliance Front panel](https://cdn.us.document360.io/0d453a50-e1da-4d4a-9409-fea7959614d8/Images/Documentation/uuid-c4b92dc4-b41c-e020-0084-fb7f7d1b4879.png?sv=2026-02-06&spr=https&st=2026-11-22T16%3A18%3A47Z&se=2026-11-22T17%3A18%3A47Z&sr=c&sp=r&sig=NkjDEvuQOvA28g8N7DJFD1P2Rh%2FWdx4Aw5O2%2FygH%2BAE%3D) | | --- | | Label | Description | | --- | --- | | 1 | System ID button with integrated indicator light | | 2 | NMI button (recessed, tool required for use) | | 3 | NIC 1 activity indicator light | | 4 | System status indicator light | | 5 | Power button with integrated indicator light | | 6 | Hard drive activity indicator light | | 7 | System cold reset button | | 8 | NIC 2 activity indicator light | Figure 7. ATD- 3200, ATD-6200 Appliance Back panel - Configuration A | ![ATD- 3200, ATD-6200 Appliance Back panel - Configuration A](https://cdn.us.document360.io/0d453a50-e1da-4d4a-9409-fea7959614d8/Images/Documentation/uuid-5bd425d5-4050-5405-dcda-7e0f56cb0659.png?sv=2026-02-06&spr=https&st=2026-11-22T16%3A18%3A47Z&se=2026-11-22T17%3A18%3A47Z&sr=c&sp=r&sig=NkjDEvuQOvA28g8N7DJFD1P2Rh%2FWdx4Aw5O2%2FygH%2BAE%3D) | | --- | Figure 8. ATD- 3200, ATD-6200 Appliance Back panel - Configuration B | ![ATD- 3200, ATD-6200 Appliance Back panel - Configuration B](https://cdn.us.document360.io/0d453a50-e1da-4d4a-9409-fea7959614d8/Images/Documentation/uuid-11e538d2-034e-4746-ce67-ae61165cbdb6.png?sv=2026-02-06&spr=https&st=2026-11-22T16%3A18%3A47Z&se=2026-11-22T17%3A18%3A47Z&sr=c&sp=r&sig=NkjDEvuQOvA28g8N7DJFD1P2Rh%2FWdx4Aw5O2%2FygH%2BAE%3D) | | --- | | Label | Interface port | | --- | --- | | 1 | Power supply module 1 | | 2 | Power supply module 2 | | 3 | Ethernet interface 0 (ATD Management Interface) | | 4 | Ethernet interface 1 (intf1) | | 5 | VGA connector | | 6 | Serial console interface | | 7 | USB 3.0 ports (3) | | 8 | BMC port (RMM) | | 9 | Ethernet interface 3 (intf3) | | 10 | Ethernet interface 2 (intf2) | ##### If an item is missing or damaged, contact your supplier. :