--- title: "Checking the average EPS using the CLI" slug: "checking-the-average-eps-using-the-cli" tags: ["Network Security (NX)", "Product Usage"] updated: 2026-09-02T17:27:05Z published: 2026-09-02T17:27:05Z canonical: "docs.trellix.com/checking-the-average-eps-using-the-cli" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.trellix.com/llms.txt > Use this file to discover all available pages before exploring further. # Checking the average EPS using the CLI Before you deploy a SmartVision appliance to a production environment, make sure that the average events per second (EPS) measured on the appliance does not exceed the recommended maximum EPS. ### Important If the average EPS measured on your Classic edition appliance exceeds the recommended maximum EPS for that model, the appliance may fail to detect some post-exploitation attacker activities. Contact Trellix Technical Support. This limitation applies to any SmartVision-enabled Network Security Classic edition appliance, whether operating in default mode (with its MVXengine enabled) or operating as a sensor (with its MVX engine disabled). ### Recommended maximum EPS rates The following paragraphs list the recommended maximum EPS rate for each appliance model, grouped by appliance type. ###### Network Security sensors This table lists the recommended maximum EPS for SmartVision-enabled Network Security sensors. The average EPS measured on your appliance should not exceed the recommended maximum value for that appliance model. | Network Security sensor model | Recommended maximum EPS | | --- | --- | | NX 2500V / NX 2501V | 300 | | NX 2550V | 750 | | NX 4500V | 1500 | | NX 6500V | 3000 | ###### Network Security integrated appliances This table lists the recommended maximum EPS for SmartVision-enabled Network Security integrated appliances. The average EPS measured on your appliance should not exceed the recommended maximum EPS for that appliance model. | Network Security integrated appliance model | Recommended maximum EPS | | --- | --- | | Default mode | Sensor mode | | NX 900 | 100 | 100 | | NX 1400 | 100 | 100 | | NX 2400 | 100 | 100 | | NX 2500 | 300 | 750 | | NX 2550 | 750 | 1500 | | NX 3500 | 1500 | 3000 | | NX 4400 / NX 4420 | 750 | 1500 | | NX 4500 | 3000 | 6000 | | NX 5500 | 7500 | 15,000 | | NX 6500 | 15,000 | 25,000 | | NX 7400 / NX 7420 | 3000 | 6000 | | NX 7500 | 3000 | 6000 | | NX 9450 | 6000 | 12,000 | | NX 10000 | 12,000 | 18,000 | | NX 10450 | 12,000 | 24,000 | | NX 10550 | 12,000 | 24,000 | ### EPS rates measured on your SmartVision appliance SmartVision appliances maintain statistics about their events-per-second rates. The statistical values are cumulative since the last time SmartVision was enabled. You can view EPS statistics by using the following CLI command: ``` show smartvision general-stats ``` The statistic that you need to check is displayed in the following line of the command output: ``` Average events per second ( ``` The output displays the following statistical values: - *x*—The minimum EPS rate sampled. - ***y***—The average of the sampled EPS rates. - *z*—The maximum EPS rate sampled. ### Important The second value, ***y***, should not exceed the recommended maximum EPS for your appliance. In the following example, the appliance has processed three events per second on average since the last time was enabled: ``` hostname # show smartvision general-stats General statistics:           .           .           .        Current events per second                                       0        Average events per second                                       (0/3/188)           .           .           . ``` ### Prerequisites - The SmartVision-enabled sensor or integrated appliance is installed in its intended location. See [SmartVision appliance placement and operational mode](/docs/requirements-5). - SmartVision monitoring has run for at least 24 hours. This allows to gather meaningful statistics. - Admin, Analyst, Monitor, or Operator access to the appliance. To check the average EPS on a SmartVision-enabled integrated appliance: 1. Log in to the appliance CLI and go to enable mode: ``` hostname > enable ``` 2. View the average EPS measured by SmartVision on your appliance. Run the `show smartvision general-stats` command. The second of the three numbers displayed in the **Average events per second** line is the average EPS measured since SmartVision was enabled. In the following example, the appliance processed three events per second on average since SmartVision was enabled: ``` hostname # show smartvision general-stats General statistics:           .           .           .        Current events per second                                       0        Average events per second                                       (0/3/188)           .           .           . ``` 3. Compare the average EPS measured on your appliance against the recommended maximum EPS for that appliance model. The recommended maximum rates are provided in [Recommended maximum EPS rates](/network-and-platform/docs/checking-the-average-eps-using-the-cli#UUID-e36caff5-b6d6-ccff-84a3-34655a617eef_id_recommen). - If the average EPS measured on your appliance is below the recommended maximum EPS for that model, you can operate this appliance in a SmartVision deployment. - If the average EPS measured on your Classic edition appliance exceeds the recommended maximum EPS for that model, the appliance may fail to detect some post-exploitation attacker activities. Contact Trellix Technical Support. :