--- title: "clock timezone" slug: "clock-timezone" tags: ["Reference", "CMS 11.x", "EX 11.x", "HX 10.x", "FX 11.x", "AX 11.x", "NX 11.x", "IVX 11.x", "Customer", "Network Security"] updated: 2026-08-04T17:22:17Z published: 2026-08-04T17:22:17Z canonical: "docs.trellix.com/clock-timezone" stale: true --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.trellix.com/llms.txt > Use this file to discover all available pages before exploring further. # clock timezone ### Description Sets the time zone on the FireEye appliance. The time zone is for display purposes and should match other security device settings. > [!NOTE] > Note > > The Z character in syslog output indicates that the time displayed is in the UTC time zone; for example: Oct 19 2012 16:10:10 Z. Use the no form of this command to delete the time zone or to reset the time zone on the FireEye appliance to Greenwich Mean Time (GMT). ### Syntax [no] clock timezone tzone ### Parameters | **tzone** | Enter one of the following areas, and then type “?” to view the specific time zones in that area: - Africa - America - Antarctica - Arctic - Asia - Atlantic_Ocean - Australia - Europe - Indian_Ocean - Pacific_Ocean - UTC - UTC-offset If you enter UTC-offset (Coordinated Universal Time), you must also enter one of the following: - UTC+hours. Number of hours (1 to 12) after UTC - UTC-hours. Number of hours (1 to 14) before UTC | | --- | --- | ### Example The following example sets the time zone to eight hours after UTC. ```plaintext hostname (config) # clock timezone UTC-offset UTC+8 ``` The following example also sets the time zone to Pacific Standard Time. ```plaintext hostname (config) # clock timezone America North United_States Pacific ```