--- title: "Common problems and solutions" slug: "common-problems-and-solutions" tags: ["Hardware", "IPS 11.1.x"] updated: 2026-09-17T07:33:43Z published: 2026-09-17T07:33:43Z canonical: "docs.trellix.com/common-problems-and-solutions" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.trellix.com/llms.txt > Use this file to discover all available pages before exploring further. # Common problems and solutions This section lists some common installation problems and their solutions. | Problem | Possible Cause | Solution | | --- | --- | --- | | Network or link problems | Improper cabling or port configuration | Ensure that the transmit and receive cables are properly connected to the fail-open switch. | | The sensor LED is off. | The Sensor is turned off. The Sensor port cable is disconnected. | Restore Sensor power. Check the Sensor cable connections. | | The sensor is operational but is not monitoring traffic. | Network device cables have been disconnected. The Sensor ports have not been enabled in the Sensor. | Check the cables and ensure that they are properly connected to both the network devices and the fail-open switch. Ports are disabled on a Sensor failure; they must be re-enabled in the Manager for the Sensor monitoring to resume. | | Runts or giants errors on switches and routers | Improper cabling or port configuration | Ensure that the transmit and receive cables are properly connected to the fail-open switch. | | The system fault “Switch absent” appears on the **Operational Status** page of the Manager. | Improper cabling | Ensure that the transmit and receive cables are properly connected to the fail-open switch. |