| Operating Condition/Mode | M-1250/M-1450 | NS3100/NS3200 | NS3500 |
|---|---|---|---|
| TAP | External tap is supported; no support for internal tap. No negotiation with peer devices. | ||
| SPAN | Dongles not required. | ||
| Inline fail-close | Dongles not required for both ports to fail-close. | ||
| Inline fail-open (Default) | Does not require external passive Fail-open Kit. | ||
| Inline fail-open (Active Fail-open Kit) | Supported with ports configured in fail-close (no dongles). | No dongles needed. Inline ports default configuration is Inline Fail Open. | Not supported. |
| Link Failure - inline fail-close | Ports fail-close and traffic is disrupted. | ||
| Link Failure - inline fail-open | Ports are admin disabled, put into bypass, and no traffic is disrupted. | Built in. Ports are admin disabled, put into bypass, and no traffic is disrupted. | Built in. Ports are admin disabled, put into bypass, and no traffic is disrupted. |
| Link Failure - inline fail-open (Active) | Ports are not admin disabled, put into bypass, and no traffic is disrupted. | Not supported. | |
| Port Speed/Duplex | 10/100/1000, Full/Half only for 10/100. | ||
| Auto negotiation | Supported and can be configured from the Manager. | Not supported. | |
| Sensor Power off - inline fail-close | Ports fail-close and traffic is disrupted. | ||
| Sensor Power off - inline fail-open | Ports fail-open, put into bypass, and no traffic is disrupted. | ||
| Warm reboot - inline fail-open (CLI reboot or reboot due to error and watchdog on) | Ports are admin disabled and put in bypass before the Sensor reboots. No traffic is disrupted. | ||
| Warm reboot - inline fail-close (CLI reboot or reboot due to error and watchdog on) | Ports remain enabled fail-close, traffic disruption till the Sensor is up. | ||
| Resetconfig | Options to either restore defaults or to retain the current port configuration are available. | ||
| Port link LED interpretation - inline fail-open | Green indicates up and inline; OFF indicates bypass. | ||
| Port link LED interpretation - inline fail-close | OFF indicates down and traffic is disrupted. | ||
| Port link LED interpretation during reboot/Sensor power down - inline fail-open | OFF indicates bypass and no traffic is disrupted. | ||
| Port link LED interpretation during reboot/Sensor power down - inline fail-close | OFF indicates down and traffic disrupted. | ||
| Front panel LED for Normal/Bypass operations - inline fail-open | Green indicates up and inline; OFF indicates bypass. | ||
| Front panel LED for Normal/Bypass operations - inline fail-close | Always on (green), normal operation. | ||
| Front panel LED for Normal/Bypass operations - SPAN | Always on (green), normal operation. | ||
| Front panel LED for Normal/Bypass operations - TAP | Always on (green), normal operation. | ||
| Link Events | Has support to control fail-open/bypass operation. | ||
| Port density | 1A/1B through 4A/4B. | 1 through 8. | 1 through 4. |
| Auto MDIX support | Supported by default (not configurable through CLI). | ||
| The Manager port configuration panel - link status color coding | The color codes are:
|
||
| The Manager port config panel - Inline/Bypass status color coding | Four separate bypass buttons, one button per port pair:
|
||
| The Manager port status at Link failure - inline fail-open | Gray | ||
| The Manager port status at Link failure - inline fail-close | Red | ||
| The Manager port status at Link failure - SPAN | Red | ||
Comparison between M-1250/M-1450, NS3100/NS3200, and NS3500 FE ports