Configuration of gigabit ethernet inline fail open - passive status

Prev Next

When deploying your Gigabit Ethernet ports in Inline Fail Open - Passive mode, you must verify RJ-11 to RJ-45 control cable connection is in place between X1(RJ-11)NS7500 and PFO(RJ-45) control ports.

Note

Fail-open operation for GE ports requires use of the optional Bypass Switch provided in the Gigabit Fail-Open Bypass Kits (sold separately).

Tip

For more information on steps on how to properly connect your Sensor for GE Inline Fail-Open functionality, see Trellix Intrusion Prevention System Installation Guide.

The port status and operating mode status for Manager fail-open passive for NS-series Sensors are as follows::

Inline Fail Open - Passive port status

Operating Mode Status on PFO

Present

The inline fail open - passive kit is in inline fail-open mode.

Bypassing

The inline fail open - passive kit is in bypass mode. The bypass switch has been activated. The sensor does not monitor traffic during this time. For example, when sensor ports are administratively disabled.

Unknown

Unable to get the status of the inline fail-open passive kit. For example, when the control cable is unplugged.

N/A

Not Applicable; the operating mode is not in inline fail open - passive mode.