--- title: "Configure 40 Gbps (QSFP+) monitoring ports" slug: "configure-40-gbps-qsfp-monitoring-ports-3" tags: ["Product Usage", "IPS 11.1.x"] updated: 2026-11-19T12:29:02Z published: 2026-11-19T12:29:02Z canonical: "docs.trellix.com/configure-40-gbps-qsfp-monitoring-ports-3" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.trellix.com/llms.txt > Use this file to discover all available pages before exploring further. # Configure 40 Gbps (QSFP+) monitoring ports Configuration of monitoring ports enables you to set the operating mode of your ports, change port speeds or specify whether you are using Trellix certified modules, and/or choose the corresponding response port for device action. 1. Go to **Devices** → **** → **Devices** → **** → **Setup** → **Physical Ports**. 2. Double-click on the row of numbered 40 Gbps (QSFP+) monitoring port. The **Monitoring Port Details** window is displayed. **Configure Monitoring Port window**![Configure Monitoring Port window](https://cdn.us.document360.io/0d453a50-e1da-4d4a-9409-fea7959614d8/Images/Documentation/uuid-7f6707ac-ae23-d648-f6ba-29f0c8636c76(7).png?sv=2026-02-06&spr=https&st=2026-11-20T13%3A40%3A58Z&se=2026-11-20T14%3A40%3A58Z&sr=c&sp=r&sig=Wx4%2B%2FtAa0uji7mbQueq3nfxdhxjQkEJYcui%2FPFJXZRI%3D) > [!NOTE] > Note > > The speed is automatically set to **40 Gbps** on the 40 Gigabit Ethernet ports. However, you can specify whether the modules are Trellix Certified. 3. Select the **State** as either **Enabled** (on) or **Disabled** (off). The **Link** displays **Up** (on) or **Down** (off) accordingly. > [!NOTE] > Note > > If your **Link** displays as **Down** and your **State** is **Enabled**, there may be a problem. Check the system faults in the **Faults** tab in **Logs** page for more information. 4. Select a **Mode** from the following: > [!WARNING] > Caution > > Your device connections must match the selected operating mode for correct system functionality. Improper deployment may result in system faults, including missed attacks and system failure. - **Inline Fail Open – Active** - **Inline Fail Closed** > [!NOTE] > Note > > Inline fail-open and Inline fail-closed are determined by how the port cables are connected. Fail-open operation for GE ports requires use of the optional Bypass Switch provided in the Gigabit Optical Fail-Open Bypass Kit (sold separately). You should *not* select the **Inline Fail Open** option if the optional external Bypass Switch is not present. - **SPAN or Hub** - **Tap** GE ports can only be configured for External Tap mode. > [!NOTE] > Note > > The **Inline Fail Open – Passive** mode is not supported with the NS9x00-series Sensors. Since the QSFP+ transceivers are supported only with the NS9x00-series Sensors, the **Inline Fail Open – Passive** mode is not supported as well. If a port is functioning as part of a *Port Pair*, the *Peer Port* is listed. For example, if port G2/1 is configured for Tap mode, port G2/2 is listed as the Peer Port. All ports are wire-matched internally with a single peer. For example, G2/1-G2/2 make up a port pair. 5. Select **Placement** of your network where the current port is connected: **Inside Network** or **Outside Network**. This step applies to **Tap** or **Inline** modes only. 6. Wherever applicable, select a **Response Port**. The following choices are available: - **This Port**: Respond out of the detection port to the segment. This is selected by default for Inline and SPAN operating modes. - **R1**: Sends responses through a R1 port - **R2**: Sends responses through a R2 port > [!TIP] > Tip > > You can assign a response port to more than one device monitoring port. However, knowing where your response ports are connected in the network will make for the best response system. 7. Click **Save** to save changes. A confirmation page is displayed. A window is displayed to confirm the changes. Click **OK** to confirm changes.