--- title: "Configure Active Fail-Open kits 18 and 19" slug: "configure-active-fail-open-kits-18-and-19-2" tags: ["Product Usage", "IPS 11.1.x"] updated: 2026-11-19T12:31:15Z published: 2026-11-19T12:31:15Z canonical: "docs.trellix.com/configure-active-fail-open-kits-18-and-19-2" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.trellix.com/llms.txt > Use this file to discover all available pages before exploring further. # Configure Active Fail-Open kits 18 and 19 **Prerequisites:** For each Active Fail-Open configuration, you will need to make sure you have all these components. - Determine the IP address for the Active Fail-Open switch or, if you are deploying multiple switches, a range of IP addresses - Determine a network mask and the default gateway for the Active Fail-Open switch - 4 cables to connect the Active Fail-Open switch and the Sensor - An RJ-45 RS232 cable to access the Active Fail-Open switch CLI - QSFP28 for NS9500 Sensors - Cables for a fiber Active Fail-Open switch: - LC and MTP/MPO fiber cables for network ports - LC and MTP/MPO fiber cables for monitor ports Broadly, these are the steps you will need to follow to set up an Active Fail-Open kit. > [!NOTE] > Note > > While configuring the 100G Active Fail-Open chassis, you must enable Forward Error Correction (FEC) in the AFO configuration. To enable FEC, go to **AFO Configuration** → **Module ** → **Advanced Features** and enable **Net 0 FEC**, **Net 1 FEC**, **Mon 0 FEC**, and **Mon 1 FEC**.