--- title: "Configure the Sensor monitoring ports in the Active Fail-Open mode" slug: "configure-the-sensor-monitoring-ports-in-the-active-fail-open-mode" tags: ["Hardware", "IPS 11.1.x"] updated: 2026-09-17T07:33:43Z published: 2026-09-17T07:33:43Z canonical: "docs.trellix.com/configure-the-sensor-monitoring-ports-in-the-active-fail-open-mode" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.trellix.com/llms.txt > Use this file to discover all available pages before exploring further. # Configure the Sensor monitoring ports in the Active Fail-Open mode You configure the Sensor monitoring ports from the Manager interface. The port configuration must match the cabling of the switch, and the ports must be set to "In-line Fail-open Active (Port Pair)" and must be enabled. **Steps:** 1. In the Manager interface, select **Device List** → **Sensor_Name** → **Physical Device** → **Port Settings**. 2. Click a numbered port (for example G1/1) from monitoring ports. The Configure Monitoring Port window displays current port settings. ![GUID-41C7AF9D-9FE9-4A72-90F5-A25EDECAE574-low.png](https://cdn.us.document360.io/0d453a50-e1da-4d4a-9409-fea7959614d8/Images/Documentation/uuid-c5658c74-2c4e-b126-7667-9a83a67b372b.png?sv=2026-02-06&spr=https&st=2026-11-20T13%3A50%3A56Z&se=2026-11-20T14%3A50%3A56Z&sr=c&sp=r&sig=urpo1SzT2dItx45am1wtWIE1KI6KsIW4bvL8NM1a6Qw%3D) 3. In the **Port Configuration**, do the following. 1. Enable the check box **Use Only McAfee Certified QSFP+**. 4. Select the **Administrative Status** to Enable (On). 5. Select the **Operating Mode** as In-line Fail-open Active (Port Pair). 6. The message "Are the Active Fail-open Kit connected?" Select Yes that you have already connected the Bypass Switch. 7. Select the area of your network to which the current port is connected: Inside (internal) or Outside (external) 8. Click **OK**. 9. Open the Bypass Switch HyperTerminal session. 10. Repeat steps 1-8 for any other ports you need to configure. For more information on configuring monitoring ports, see the *Trellix Intrusion Prevention System Product Guide*. 11. Download the changes to your Sensor.