Configuring HTTP access to install software updates using the CLI

Prev Next

Use the commands in this topic to configure HTTP access to install software updates from a USB device onto the appliance. By default, you can access only the contents locally in the fireeye directory for the first partition from a specified URL.

Note

The Central Management System appliance does not host guest images when it is operating in "inline" mode.

Prerequisites

To configure HTTP access to install software updates from a USB device:

  1. Go to CLI configuration mode:

    hostname > enable
    hostname # configure terminal
  2. Enable HTTP access on the loopback interface on the appliance:

    hostname (config) # media usb web-access enable local

    Local web access is enabled by default.

  3. Specify the top-level directory as the location to extract software updates on a USB device:

    hostname (config) # media usb web-access top-dir fireeye

    This directory will be used as the URL to extract the software on the USB device. For example, if you specified the install directory as fireeye/gi-13.0701, the URL for the installation is http://localhost/media/usb1/fireeye/gi-13.0701.

  4. Verify that the USB device is mounted:

    hostname (config) # show media usb
    USB auto-mount configuration:
      Enabled:             yes
      Local web access:    yes
      Top-level directory: fireeye
    USB auto-mount status:
      Device mounted:      yes
      Access URL:          N/A
  5. Download software updates using the specified URL as the location to install the updates. See Installing guest images from a USB device using the CLI for a representative procedure.