--- title: "Connect the cable for Sensor failover" slug: "connect-the-cable-for-sensor-failover-2" tags: ["Hardware", "IPS 11.1.x"] updated: 2026-09-17T09:43:52Z published: 2026-09-17T09:43:52Z canonical: "docs.trellix.com/connect-the-cable-for-sensor-failover-2" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.trellix.com/llms.txt > Use this file to discover all available pages before exploring further. # Connect the cable for Sensor failover For Sensor failover, connect two NS3x00 Sensors using the appropriate ethernet cables. These two Sensors must be running the same software version. Refer to the following table before you configure a HA pair: | Sensor Model | Port to connect the HA pair | Cable requirements for failover | | --- | --- | --- | | NS3100/NS3200 | 1 | Ethernet copper cable (minimum Category 5e) | **Steps:** 1. Plug the cable into port 1 of the active NS3x00 Sensor. 2. Connect the other end of the cable into port 1 of the standby NS3x00 Sensor. Only port 1 is required for failover to function properly.