--- title: "Connections with the fail-open switch" slug: "connections-with-the-fail-open-switch-1" tags: ["Hardware", "IPS 11.1.x"] updated: 2026-08-19T18:44:28Z published: 2026-09-17T07:33:47Z canonical: "docs.trellix.com/connections-with-the-fail-open-switch-1" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.trellix.com/llms.txt > Use this file to discover all available pages before exploring further. # Connections with the fail-open switch To accurately detect attacks, a Sensor must be aware of which traffic is outside the network and which traffic is inside. Identifying traffic direction is accomplished through the proper cabling of the fail-open switch as well as the appropriate port configuration of the Sensor monitoring ports in the Trellix Intrusion Prevention System Manager. The passive fail-open switch consists of the ports mentioned in the picture below. ![GUID-0CBD6AFA-DD50-46BF-990F-CDF032790537-low.png](https://cdn.us.document360.io/0d453a50-e1da-4d4a-9409-fea7959614d8/Images/Documentation/uuid-0ecbb34e-d458-022c-5c4c-54f5b9a4c8c9.png?sv=2026-02-06&spr=https&st=2026-11-20T15%3A40%3A58Z&se=2026-11-20T16%3A40%3A58Z&sr=c&sp=r&sig=mgvvHbu0eSRL7XkYbg%2BHbDkiDAQ9aPZ6R5aT4P3F%2BqA%3D) | Field | Description | | --- | --- | | 1 | To Sensor Fail-Open Control port | | 2 | To network device (inside) | | 3 | To network device (outside) | | 4 | (inside) Plugs into Sensor port Gy/a (NS-Series) | | 5 | (outside) Plugs into Sensor port Gy/b (NS-Series) |