Critical faults are the highest severity faults and generally indicate a serious issue. See the Action column for potential troubleshooting tips.

Critical faults

Fault

Description/Cause

Action

Endpoint Intelligence Service is down

Endpoint Intelligence Service has not started as the ePO is not reachable.

Make sure that the ePO server is up and running and is reachable to NTBA.

Endpoint Intelligence Service has not started as the ePO extension does not support auto-signing service.

Make sure that the ePO server supports ePO Auto Signing functionality (Change on Name confirmation).

Endpoint Intelligence Service has not started because of authentication error connecting to the ePO server.

Provide valid ePO Server credentials.

Endpoint Intelligence Service has not started because of internal error from the ePO server.

ePO server responded error; look at the ePO logs.

Endpoint Intelligence Service has not started because of unexpected errors.

Look at the ePO server and NTBA logs for the error, and try again.

Endpoint Intelligence Service has not started because of corrupt certificate.

Certificate invalid; retry saving again.

Endpoint Intelligence Service has not started because the configured port for Endpoint Intelligence Service is already in use.

This port is already in use; configure an unused port.