The FIPS Sensor boot-up executes all the FIPS compliant algorithms, as part of the pre-operational self-tests, firmware integrity tests, and known answer tests (KAT).
If a self-test fails, the Sensor enters into error state and reboots continuously. User needs to netboot the Sensor with a valid firmware to come out of the error state. A user can refer to the console log to view which self-test has failed.
Similarly, Manager executes power-up self tests and software integrity tests. Failure of self-tests will cause the module to transition to an error state. Logical components will shut-down and no data output will be provided during error states. User needs to install a valid software image to come out of the error state. Users can refer to the console log to view which self-test has failed. Additionally, users can refer to ems.log for more details.
The Random Number Generation (RNG) functionality does not require any manual configuration and is initialized on startup.