--- title: "(Either) Connect a copper fail-open switch" slug: "either-connect-a-copper-fail-open-switch-1" tags: ["Hardware", "IPS 11.1.x"] updated: 2026-09-17T07:33:43Z published: 2026-09-17T07:33:43Z canonical: "docs.trellix.com/either-connect-a-copper-fail-open-switch-1" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.trellix.com/llms.txt > Use this file to discover all available pages before exploring further. # (Either) Connect a copper fail-open switch **Prerequisites:** - You require two Cat 5/Cat 5e Ethernet cables to connect your fail-open switch to the Sensor. - You require two copper SFP modules to be inserted into two corresponding unused modular sockets on the Sensor. > [!TIP] > Tip > > For more details about your Sensor and SFP modules, refer to the *Trellix Intrusion Prevention System NS-series Sensor Product Guide* for the appropriate model. - Control cable that is supplied with the fail-open kit. **Steps:** 1. Connect a Cat 5/Cat 5e Ethernet cable (inside) into the copper SFP in port **Gy/a** or **xA**, where **y** represents the module number (for NS-Series Sensors), and **x** and **a** represent port numbers. 2. Connect the other end of the cable to the port labeled **Monitor A** on the fail-open switch. 3. Connect a Cat 5/Cat 5e Ethernet cable (outside) to the corresponding **Gy/b** or **xB** peer port. (For example, if you used **G0/1** in step 1, plug the cable into port **G0/2**). 4. Connect the other end of the cable to the port labeled **Monitor B** of the fail-open switch. 5. Connect one end of the control cable to the fail-open switch **Control** port. 6. Connect the other end to the Sensor control port **Xy**, where **y** is the port number that corresponds to one of the monitoring ports. The table below shows the control ports of compatible NS-Series Sensors and the corresponding port pairs that should be used for connection. | NS-Series Sensor | Control Port | Port (inside) | Port (outside) | | --- | --- | --- | --- | | NS7x00, NS7x50, NS7500 | X1 | G0/1 | G0/2 | | NS5x00 | X1 | G1/1 | G1/2 | | X2 | G1/3 | G1/4 | | X3 | G1/5 | G1/6 | | X4 | G1/7 | G1/8 | | X5 | G1/9 | G1/10 | | X6 | G1/11 | G1/12 | **Result:** With this cable configuration, Sensor monitoring port **Gy/a** or **xA** views traffic as originating inside the network, and port **Gy/b** or **xB** view traffic as emerging outside the network. This configuration (**Gy/a** or **xA** = outside, **Gy/b** or **xB** = inside) must match the port configuration specified for this Sensor, and the ports must be configured accordingly.