--- title: "Enable layer 2 settings" slug: "enable-layer-2-settings-2" tags: ["Product Usage", "IPS 11.1.x"] updated: 2026-11-19T12:31:15Z published: 2026-11-19T12:31:15Z canonical: "docs.trellix.com/enable-layer-2-settings-2" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.trellix.com/llms.txt > Use this file to discover all available pages before exploring further. # Enable layer 2 settings Enabling the **Layer 2 Settings**action provides permission for the device to go into layer 2 pass-through mode, or fail-open mode, when there are multiple occurrences of critical device faults in a specified period of time. This feature provides another measure for preventing a bottleneck at the device when deployed in High Availability networks. > [!NOTE] > Note > > The **Layer 2 Settings** mode is on (enabled) by default. By default, if the device experiences a critical operating error, such as a suspended task or "hung" processor, it reboots. If a device continues to experience critical errors, a reboot is initiated for every critical error. If the device is not closely monitored, the constant rebooting can create a bottleneck at the device. Also, in the case of External Tap and SPAN or Hub monitoring modes, passing traffic is not being inspected. The **Layer 2 Pass-Through** mode enables you to set a threshold on the number of critical failures within a configured period of time that the device can experience before being forced into fail-open mode. For example, you configure **Layer 2 Pass-Through** mode to enable if there are three critical faults in any 10-minute period. At minutes one, three, and seven, faults occur; the Layer 2 Pass-Through Mode is enabled. Here is another scenario: at minutes one, four, eleven, and thirteen, faults occur. In this case, the last three faults occurred within 10 minutes of each other, thus the device enters Layer 2 Pass-Through mode. Device reboot may take a few minutes to complete. This downtime is not counted against the Layer 2 duration; only device uptime is counted. > [!NOTE] > Note > > The **Layer 2 Pass-Through** mode is off (not enabled) by default. This option enables fail-open operation for critical faults between Layer 3 and Layer 7 only; failures at Layer 1 and Layer 2 continue to cause a reboot of the device. > [!NOTE] > Note > > The Manager provides the capability to allow Layer 2 bypassing to a Sensor directly from the Manager interface, rather than having to do it from the CLI. The modes **Assert** and **Deassert** could now be set from the Manager interface. For more details on enabling the modes, refer to [Enable Layer 2 Modes](/network-and-platform/docs/enable-layer-2-modes-2). The following occurs when Layer 2 Pass-Through Mode is activated: - Processing of traffic on all monitoring ports of the affected device ceases. - The device sends a fault message to the Manager indicating that it is now in Layer 2 Pass-Through mode. **Steps:** 1. For a standalone Sensor, click **Devices** → **** → **Devices** → **** → **Troubleshooting** → **Layer 2 Bypass**. For Sensors in a stack, Click **Devices** → **** → **Devices** → **** → **Member Sensors** → **** → **Troubleshooting** → **Layer 2 Bypass**. 2. Select **Yes** to enable **Layer 2 Pass-Through Monitoring**. 3. Enter a **Trigger After** value. The threshold determines the number of critical failures within the **Occurring Within** time before switching to pass-through mode. 4. Enter an **Occurring Within** time. This time represents the number of minutes within which the **Trigger After** value must be met to switch into pass-through mode. **Layer 2 Settings window**![Layer 2 Settings window](https://cdn.us.document360.io/0d453a50-e1da-4d4a-9409-fea7959614d8/Images/Documentation/uuid-cff6a0d7-559b-c736-60d7-486244dac14c(7).jpg?sv=2026-02-06&spr=https&st=2026-11-20T08%3A50%3A15Z&se=2026-11-20T09%3A50%3A15Z&sr=c&sp=r&sig=VBZ17HKnjMY2CF6dIGLngCgi9Jz6F%2FNDJ8snTLLBDo0%3D) 5. Select yes to enable **ARP Spoofing** on the device. 6. Click **Save**. Once applied, you can view the number of critical faults and current mode in the **Layer 2 Pass-Through Status** dialog at the bottom of the screen. **Layer 2 Pass-Through Status dialog**![Layer 2 Pass-Through Status dialog](https://cdn.us.document360.io/0d453a50-e1da-4d4a-9409-fea7959614d8/Images/Documentation/uuid-fed52401-b07f-3155-b81c-74657593248a(7).png?sv=2026-02-06&spr=https&st=2026-11-20T08%3A50%3A15Z&se=2026-11-20T09%3A50%3A15Z&sr=c&sp=r&sig=VBZ17HKnjMY2CF6dIGLngCgi9Jz6F%2FNDJ8snTLLBDo0%3D) Note the following status fields: - **Occurrences**: current number of threshold-breaching events. - **Current Mode**: current mode of the device. **Normal** means that Layer 2 pass-through mode is not enabled in the device. **L2 Pass-Through Mode** means pass-through mode is enabled.