--- title: "Enable tap mode for the Fail-Open module" slug: "enable-tap-mode-for-the-fail-open-module" tags: ["Hardware", "IPS 11.1.x"] updated: 2026-08-19T18:44:18Z published: 2026-09-17T07:33:47Z canonical: "docs.trellix.com/enable-tap-mode-for-the-fail-open-module" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.trellix.com/llms.txt > Use this file to discover all available pages before exploring further. # Enable tap mode for the Fail-Open module **Prerequisites:** - Configure an IPv4 address for your Active Fail-Open chassis. - Make sure you can access the Active Fail-Open chassis web interface using a web browser. You can enable tap mode for your Active Fail-Open chassis if you use a tap to route network traffic to the Sensor Monitoring ports. **Steps:** 1. Log on to the web interface of the Active Fail-Open chassis. Use default credentials to access the web interface. > [!NOTE] > Note > > Make sure that you have selected the correct module. You can also change the module from the CLI command prompt using the `set_seg x y` CLI command. Here `x` is the module number and `y` is the segment. 2. Click the **Bypass** tab to access the **Bypass** configuration page. 3. Click the **HB active mode** drop-down menu and select **Off**. 4. In the **Active bypass** section, select **tap**. ![GUID-DF6C4452-DFDE-48BD-9141-32D24F251DAD-low.jpg](https://cdn.us.document360.io/0d453a50-e1da-4d4a-9409-fea7959614d8/Images/Documentation/uuid-a9076f81-b698-b673-8d32-a6975830425f.jpg?sv=2026-02-06&spr=https&st=2026-11-20T20%3A31%3A57Z&se=2026-11-20T21%3A31%3A57Z&sr=c&sp=r&sig=TxGsMGXXnV5uVboLTUxk10%2BgjOVV3GyDw23ZTbxYjoM%3D) 5. Click **Apply** to save your configuration. **Result:** You have set your active fail-open to tap mode of operation.