You can configure the SNMP server to which alert information for Sensor is to be sent.
You can configure more than one SNMP server. You can configure the SNMP servers for each admin domain separately. The SNMP server configured for a root admin domain can be different from the SNMP server configured for its child domains. When the Children and the Current checkboxes are selected while configuring an SNMP server for the root admin domain, the SNMP server configured for the child domain will forward notifications to both the parent and child domain SNMP servers. When the Children checkbox is not selected in the root admin domain, then the child domain will use only the SNMP server configured for that domain to forward notifications. The SNMP Servers list on the SNMP tab displays the SNMP servers you have configured.
Select Manager → <Admin Domain Name> → Setup → Notification → IPS Events → SNMP.
The SNMP tab is displayed where Enable SNMP Notification option and the configured SNMP Servers list is displayed.
.png)
Select Yes against Enable SNMP Notification and click Save.
The columns displayed under the SNMP Servers section are as follows:
Field
Description
Profile Name
The profile name from where notifications are sent
IP Address
IP address of the target server
UDP Port
SNMP listening port of the target server
SNMP Version
The version of SNMP server
Notification Logic
The logic by which the notifications are sent to the target server