--- title: "Full-duplex setting" slug: "full-duplex-setting" tags: ["Product Usage", "IPS 10.1.10"] updated: 2026-10-05T15:41:06Z published: 2026-10-05T15:41:06Z canonical: "docs.trellix.com/full-duplex-setting" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.trellix.com/llms.txt > Use this file to discover all available pages before exploring further. # Full-duplex setting When operating at full-duplex, FCS, cyclic redundancy checks (CRC), alignment errors, and runt counters should be minimal. If the link is operating at full-duplex, the collision counter is not active. If the FCS, CRC, alignment, or runt counters are incrementing, check for a duplex mismatch. Duplex mismatch is a situation in which the switch is operating at full-duplex and the connected device is operating at half-duplex, or vice versa. The result of a duplex mismatch is extremely slow performance, intermittent connectivity issues, and loss of connection. Other possible causes of data link errors at full-duplex are bad cables, a faulty switch port, or software and/or hardware issues.