The new docs.trellix.com features a modernized UI and AI-powered conversational search. Content is currently available in English, with additional languages launching in early November 2026. We hope you enjoy the updated experience.

getccstats

Prev Next

The getccstats command displays the statistics of the Sensor control channel module.

Syntax:

getccstats

Sample Output:

IntruDbg#> getccstats

sigfile tables = accessible.

manager-sensor trust = established.

sensor installation = complete

alert channel = up

peer alert channel = down

throttleThreshold = 1.

throttleInterval = 0.

throttleAction = 1.

failoverAction = 2.

failoverStatus = 3.

peerStatus = 5.

fail-open Action = 2.

rxSysEvCount = 14.

putSysEvUnCount = 0.

rxSysEvDecodeUnCount = 8.

txSysEvCount = 14.

rxSigAlertCount = 0.

rxScanAlertCount = 0.

rxDosAlertCount = 0.

rxTSMaliciousAlertCount = 0.

txAlertCount-Primary = 0.

txAlertCount-Secondary = 0.

txPerfAlertCount-Primary = 13.

txPerfAlertCount-Secondary = 0.

txAppIdStatsAlertCount-Primary = 0.

txAppIdStatsAlertCount-Secondary = 0.

throttleCount = 0.

copyPortDropCount = 0.

unknownPortInStandbyDropCount = 0.

rxAlertDecodeUnCount = 0.

rxCorrFlagReAlertCountt = 0.

rxScanFilterReAlertCount = 0.

rxShellCodeAlertCount = 0.

sslConflictAlertCount = 0.

sslConflictTimeCount = 0.

rxAlertFromCECount = 0.

txAlertToCECount = 0.

AlertsInRngBufPriCount = 0.

AlertsInRngBufSecCount = 0.

PutAlertInRngBufUnCount = 0.

ScanCorrAlertLogSubNodeThrottleOnCount = 0.

ScanCorrAlertLogNodeFlowOffCount = 0.

ScanCorrAlertLogSubNodeAddCount = 0.

ScanCorrAlertLogSubNodeAddFailedCount = 0.

ScanCorrAlertLogNodeAddCount = 0.

ScanCorrAlertLogNodeAddFailedCount = 0.

ScanCorrLogIdZeroCount = 0.

ScanCorrLogIdNonZeroCount = 0.

DummyAddLogNodeAddCount = 0.

DummyAddAlertLogNodeAddFailedCount = 0.

DummyAddLogSubNodeAddCount = 0.

DummyAddAlertLogSubNodeAddFailedCount = 0.

DummyAddLogSubNodeThrottleOnCount = 0.

DummyAddLogSubNodeThrottleOffCount = 0.

DummyAddLogNodeFlowOffCount = 0.

DummyFoundLogSubNodeThrottleOnCount = 0.

DummyFoundLogSubNodeThrottleOffCount = 0.

DummyFoundLogNodeFlowOffCount = 0.

DummyFoundLogNodeAlreadyThrottledCount = 0.

DummyFoundLogNodeCopyPortOffCount = 0.

AddLogNodeAddCount = 0.

AddLogNodeAddFailedCount = 0.

AddLogSubNodeAddCount = 0.

AddLogSubNodeAddFailedCount = 0.

AddLogSubNodeThrottleOnCount = 0.

AddLogSubNodeThrottleOffCount = 0.

AddLogNodeFlowOffCount = 0.

FoundLogSubNodeThrottleOnCount = 0.

FoundLogSubNodeThrottleOffCount = 0.

FoundLogNodeAlreadyThrottledCount = 0.

FoundLogNodeFlowOffCount = 0.

FoundLogNodeWasOrigDummyNodeCount = 0.

FoundLogSubNodeWasOrigDummyNodeCountNowThrottled = 0.

FoundLogSubNodeWasOrigDummyNodeCountNowNotThrottled = 0.

aclAlertThrottleMaxIpPair = 10.

aclAlertThrottleInterval = 120.

aclAlertThrottleAction = 1.

aclAlertThrottleThreshold = 5.

aclAlertDirectToSyslog = 2.

rxAclAlertCount = 0.

aclThrottleCount = 0.

txAclAlertCount = 0.

ezAlertThrottleMaxIpPair = 10.

ezAlertThrottleInterval = 120.

ezAlertThrottleAction = 1.

ezAlertThrottleThreshold = 5.

ezAlertDirectToSyslog = 0.

rxEzAlertCount = 0.

ezThrottleCount = 0.

txEzAlertCount = 0.

LogIdNodeListCount = 0.

GrpIdNodeListCount = 0.

LogIdListPtr = 0.

LogIdBlockPtr = 0.

LogIdSubListPtr = 0.

LogIdSubBlockPtr = 0.

LogIdHTPtr = 0.

GrpIdListPtr = 0.

GrpIdBlockPtr = 0.

GrpIdHTPtr = 0.

RxCorrSigAlertFromCECount = 0.

DatapathAlertSBFloodOnCount = 0.

RxSigAlertWithPLCount = 0.

RxPSAlertWithPLCount = 0.

RxHSAlertWithPLCount = 0.

TxPLlistDropMsgCount = 0.

TxPLlistSendMsgCount = 0.

fwdChangePLModeReqCount = 0.

fwdDelPLMsgCount = 0.

RxUnknown MsgId Count = 0.

Reboot/Wrap Count = 2015.

PL Reboot/Wrap Count = 2015.

purgeCnt0 = 0.

purgeCnt1 = 0.

AlertsInRngBufPriCount = 0.

AlertsInRngBufSecCount = 0.

PutAlertInRngBufUnCount = 0.

osfpUpdateMsgRxCnt = 0.

osfpInactivateMsgRxCnt = 0.

osfpMacOnlyDelMsgRxCnt = 0.

osfpUpdateMsgTxCnt = 0.

osfpInactivateMsgTxCnt = 0.

osfpMacOnlyDelMsgTxCnt = 0.

osfpBulkUpdateMsgRxCnt = 0.

osfpBulkInactivateMsgRxCnt = 0.

osfpBulkUpdateMsgTxCnt[EMS_PRIMARY] = 0.

osfpBulkUpdateMsgTxCnt[EMS_SECONDARY] = 0.

osfpBulkInactivateMsgTxCnt[EMS_PRIMARY] = 0.

osfpBulkInactivateMsgTxCnt[EMS_SECONDARY] = 0

Applicable to:

NS-series Sensors