--- title: "Import a Sensor configuration file" slug: "import-a-sensor-configuration-file" tags: ["Product Usage", "IPS 10.1.10"] updated: 2026-10-05T15:40:08Z published: 2026-10-05T15:40:08Z canonical: "docs.trellix.com/import-a-sensor-configuration-file" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.trellix.com/llms.txt > Use this file to discover all available pages before exploring further. # Import a Sensor configuration file ## Before you begin The Manager from which configuration is exported and the one to which configuration is imported must be identical. They should be of the same model, and same software version. Both Managers must have the same admin domain hierarchy, or at a minimum, the same admin domain hierarchy starting from the domain wherein the Sensor resides. For example, if you exported a Sensor belonging to /My Company/Domain A, and below Domain A, there is: - /My Company/Domain A/Domain B - /My Company/Domain A/Domain B/Domain C The importing Sensor must reside in a domain that has the following sub-domains: - Domain B - Domain B/Domain C > [!NOTE] > Caution > > Trellix recommends that the Sensor receiving the import has the same signature set as the exporting Sensor. It is recommended that both the Managers have the same set of policies if policies have also been exported/imported. The **Import Configuration** option enables you to overwrite the current configuration on a saved (exported) Sensor configuration file. Importing a saved configuration is useful in a test-to-production environment where you configure your settings on a test (non-production) Manager system, then import to a Sensor in your live environment. Importing is also useful in the event a Sensor fails and you replace the failed Sensor with a new Sensor, which requires the same configuration as the previous Sensor. ## Task 1. Select **Devices** → **** → **Devices** → **** → **Maintenance** → **Import Configuration**. > [!NOTE] > Note > > The **** here refers to a Sensor. The **Import Configuration** page is displayed. 2. Click **Browse** to locate your saved Sensor configuration. 3. Click **Apply**. 4. Upon completion of import, reboot the Sensor. 5. Run a Sensor report to verify settings.