--- title: "latency-monitor restore-inline" slug: "latency-monitor-restore-inline-3" tags: ["Product Usage", "IPS 11.1.x"] updated: 2026-11-19T12:29:40Z published: 2026-11-19T12:29:40Z canonical: "docs.trellix.com/latency-monitor-restore-inline-3" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.trellix.com/llms.txt > Use this file to discover all available pages before exploring further. # latency-monitor restore-inline When a high latency is observed on the Sensor and the latency monitor is configured, the Sensor remains in layer 2 until a layer 2 deassert is invoked or a Sensor reboots. This command allows the Sensor to come out of layer 2 mode without layer 2 deassert. The Sensor restores to inline from layer 2 if the following conditions are met: - The latency monitor has put the Sensor in layer 2 mode. - The Sensor is in good health. If the Sensor is in bad health, a deassert cannot be performed and the Sensor reboots. - A substantial amount of time has lapsed, as configured using this command, when the Sensor went into layer 2 due to latency. The default time to trigger an automatic layer 2 deassert is 10 minutes. If the latency continues to exist after the Sensor is restored to inline mode, the Sensor behaves as per the current setting of the latency monitor. **Syntax** `latency-monitor restore-inline enable <10-60>` `latency-monitor restore-inline disable` | Parameter | Description | | --- | --- | | <10-60> | The time to trigger the restore inline from layer 2. It is counted since the time the Sensor moved into layer 2 state due to high latency. | The `latency-monitor status` command displays the current status of the latency monitor feature, as well as the current status of the restore-inline feature of the latency monitor. **Applicable to:** NS-series Sensors