---
title: "Management port configuration"
slug: "management-port-configuration"
tags: ["Product Usage", "IPS 10.1.10"]
updated: 2026-09-06T12:33:55Z
published: 2026-10-05T15:41:20Z
canonical: "docs.trellix.com/management-port-configuration"
---
> ## Documentation Index
> Fetch the complete documentation index at: https://docs.trellix.com/llms.txt
> Use this file to discover all available pages before exploring further.
# Management port configuration
If you experience problems getting your Sensor and Manager to communicate, it might be a communication issue between the Sensor's Management port and the network device to which it is connected. Check the Management Port Link indicator lights on the Sensor. If the link is down, see if any of the following suggestions enable connectivity.
- Check that the network device is online.
- Check the cable connecting the Sensor to the network device.
- Ensure that the port on the device to which the Management port is connected is enabled and active.
- The port speed and duplex mode of the two devices must match. For example, if the device connecting to the Sensor is not set to auto-negotiate, you must configure the Management port to use the same settings as those of the device connecting to the Management port. To troubleshoot this, use the
set mgmtport command.
> [!NOTE]
> Note
>
> Check the link LEDs on the devices to see if communication is established, or use the show mgmtport command to show the link's status.
Try each of these configuration options to see if one establishes a link:
1. If possible, set the other device's port configuration to auto-negotiate. (The Sensor is set to auto-negotiate by default.)
2. Using the
set mgmtport command as described below in
*Setting the management port speed and duplex mode*, try setting the speed and port of the Sensor to
speed 100 and
duplex half or full.
3. If no link is established, try
speed 10 and
duplex half or full.
4. If none of these attempts creates a link, try setting the port on the other device to a speed of 100, duplex half or full, and try step 2 again.
5. If this does not establish a link, you can then do the same, setting the other device to a speed of 10, duplex half or full, and try step 3 again.
6. If you are still experiencing difficulties, contact
Trellix technical support.
> [!NOTE]
> Note
>
> M series Sensors' Management port support 1000 Mbps (1 Gbps) as well. Use the set mgmtport auto command to establish a link to the connecting device (before performing this, see to it that the other device's port configuration's speed is fixed to 1000 and also set to auto-negotiate).